LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2012 >> Soul Base, Automatic >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Idle Stop & Go (ISG) System - 1.6L >> AGM Battery >> Repair procedures >> Removal and Installation

Removal and Installation

  1. Remove the battery.
    1. Disconnect the battery terminals (A).

      Tightening torque 

      (+) terminal:

      7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ 7.2 lb-ft)

      (-) terminal (without battery sensor):

      7.8 ~ 9.8N.m (0.8 ~ 1.0kgf.m, 5.8 ~ 7.2lb-ft)

      (-) terminal (with battery sensor):

      4.0 ~ 6.0N.m (0.4 ~ 0.6kgf.m, 3.0 ~ 4.4lb-ft)

      Fig 1: Identifying Battery Terminals
      G08328052Courtesy of KIA MOTORS AMERICA, INC.
  2. Remove the air duct and air cleaner assembly. (Refer to ENGINE AND TRANSAXLE ASSEMBLY ).
  3. Remove the battery insulation pad.
  4. Disconnect the ECM connector (A).
    Fig 2: Identifying ECM Connector
    G08328053Courtesy of KIA MOTORS AMERICA, INC.
  5. Remove the ECM (A) and then disconnect the battery tray (B).

    Tightening torque: 

    8.8 ~ 13.7 N.m (0.9 ~ 1.4 kgf.m, 6.5 ~ 10.1 lb-ft)

    Fig 3: Identifying ECM And Battery Tray
    G08328054Courtesy of KIA MOTORS AMERICA, INC.
  6. Remove the battery tray (A).

    Tightening torque: 

    9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

    Fig 4: Identifying Battery Tray
    G08328055Courtesy of KIA MOTORS AMERICA, INC.
  7. Installation is the reverse order of removal.
    CAUTION: When installing the battery, fix the mounting bracket on the tray correctly.
    CAUTION:
    • ISG (Idle stop & go) system equipped vehicle always use the AGM battery only. If flooded battery has installed, this can potentially lead to engine electrical trouble or ISG system error.
    • Replace same capacity of the AGM battery.
    NOTE: Ensure the AGM battery is placed correctly on the battery tray.
    In all cases, an AGM battery must be installed and the battery sensor calibrated for the ISG system to function.
    After the battery has been changed or disconnected, the battery sensor must be recalibrated. After connecting the battery, start the engine at least once.
    Then park the car for at least 4 hours with the ignition off in the ignition switch OFF door closed, hood switch off state.
    After the 4 hours, the engine should be started two times.
    At this time the battery sensor will be recalibrated. (Refer to "BATTERY SENSOR RECALIBRATION PROCEDURE " in FL group.) But first 25 times, the ISG function can operates regardless of ISG system stability for ISG function operating check.
    WARNING: Do not open the AGM battery.
    The AGM battery must not be opened under any circumstances as the introduction of oxygen from the air will cause the battery to lose its chemical equilibrium and rendered non-operational.