Ground Circuit Inspection
- Ignition "OFF".
- Connect the "A/T CONTROL RELAY" connector.
- Measure the resistance between terminal "2" of the "A/T CONTROL RELAY" harness connector and chassis ground.
Specification : Approx. 0 Ω
- Is resistance within specifications?
YES
- Go to "COMPONENT INSPECTION " procedure.
NO
- Check for open in harness. Repair as necessary and Go to "VERIFICATION OF VEHICLE REPAIR " procedure.