Solenoid, Fuel Quantity: Installation
- Install a NEW
gasket (2) and O-ring seal (1) onto the fuel quantity solenoid (3) and lubricate the O-ring seal (1) with clean diesel fuel.NOTE:
Do not allow dirt or other contaminates to enter into the fuel injection pump.
- Remove the protective cap(s) from fuel injection pump.
- Install the fuel quantity solenoid (2) into the fuel injection pump and tighten the fasteners (3) to 7 N.m (62 in. lbs.).
- Connect the fuel quantity solenoid wire harness connector (1).
- Install the fuel injection pump blocker plate (7). Tighten the nuts (8) to 25 N.m (18 ft. lbs.).
- Install the charge air inlet hose.
- Connect the negative battery cable.
- Start engine and inspect for leaks.