Oil Pump Drive And CMP Sensor - 4.0L
If the CMP and oil pump drive are to be removed and installed, do not allow engine crankshaft or camshaft to rotate. CMP sensor relationship will be lost.
| 1 - OIL PUMP DRIVE ASSEMBLY |
| 2 - CMP |
| 3 - CMP ELECTRICAL CONNECTOR |
| 4 - HOUSING HOLD DOWN BOLT |
| 5 - HOUSING |
| 6 - PLASTIC COVER |
| 7 - COVER SCREWS (2) |
- Remove two plastic cover screws (7) and remove plastic cover (6). See Fig 1.
1 - OIL PUMP DRIVE HOUSING 2 - CMP SENSOR 3 - SENSOR MOUNTING BOLT 4 - TARGET WHEEL 5 - HOUSING - Note and mark rotational position of target wheel (4) in relationship to housing (5). See Fig 2.
- Disconnect CMP electrical jumper harness (3) at engine wiring harness. See Fig 1.
- Before proceeding to next step, mark and note rotational position of oil pump drive housing (5) in relationship to engine block. After installation, the CMP sensor should face the 4 o'clock position as viewed from right side of engine. See Fig 1.
- Remove hold-down bolt (4) and clamp. See Fig 1.
- Pull assembly from engine.
- Remove and discard old oil pump drive-to-engine block gasket.