Alternate Procedure
- Set parking brake and place transmission in Neutral (Drive for auto. trans.). Start engine and run at idle to obtain normal operating temperature. Turn ignition off and connect timing light using inductive pickup or adapter. Do not puncture spark plug wire.NOTE: If timing light has an adjustable advance control feature, turn the control to the "OFF" position.
- Disconnect and plug 4 in. Hg vacuum switch hose (Red and Black wires connected to switch). Disconnect distributor vacuum advance hose, and connect hose to 4 in. Hg vacuum switch. Disconnect knock sensor wire connector. Using a jumper wire, ground knock sensor wire connector to engine block. Start engine.
- With engine at idle speed (solenoid energized), check timing. If required, adjust timing to specification.
ALTERNATE TIMING SPECIFICATIONS (DEGREES BTDC @ RPM)
| Application | Man. Trans. | Auto. Trans. |
|---|---|---|
| Federal | 10 @ 680 | 10 @ 600 |
| Calif. | 10 @ 680 | 10 @ 600 |
| High Alt. | 17 @ 700 | 17 @ 650 |