| MASTER CYL PRESSURE |
Gradually depress the brake pedal |
Resistance value increases between 0.5 - 4.5 V according to the depth of brake depression. |
| MASTER CYL PRES (VDC) |
Gradually depress the brake pedal |
Resistance value increases between 0 - 25.6 MPa according to the depth of brake depression. |
| MOTOR TEMPERATURE |
Always |
115 °C or less |
| CONTROL MODULE TEMP |
Always |
150 °C or less |
| MST CYL PRES POWER VOLT |
Always |
5.00 - 5.22 V |
| STROKE SEN 1 POWER VOLT |
Always |
5.00 - 5.22 V |
| MOTOR POWER SUPPLY |
Always |
4.28 - 28.0 V |
| CONTROL MODULE POWER |
Always |
11.7 - 16.2 V |
| STROKE SEN 1 LEARN VALUE |
Always |
-0.68 - 14.78 deg |
| STROKE SEN 2 LEARN VALUE |
Always |
-0.68 - 14.78 deg |
| ALL SENSOR LEARNING |
Learning not completed |
INCOMP |
| Learning completed |
COMP |
| STROKE SEN 1 OUTPUT VOLT |
Gradually depress the brake pedal |
Resistance value increases between 0.51 - 4.59 V according to the depth of brake depression. |
| STEERING ANGLE SENSOR |
When driving straight |
0±3.5° |
| When steering wheel is steered to RH by 90° |
Approx. -90° |
| When steering wheel is steered to LH by 90° |
Approx. +90° |
| DECEL G SENSOR |
Vehicle stopped |
Approx. 0 G |
| During acceleration |
Positive value |
| During deceleration |
Negative value |
| SIDE G SENSOR |
Vehicle stopped |
Approx. 0 m/s2 |
| Right turn |
Negative value |
| Left turn |
Positive value |
| YAW RATE SENSOR SIGNAL |
Vehicle stopped |
Approx. 0 d/s |
| Right turn |
Negative value |
| Left turn |
Positive value |
| WHEEL SENSOR FRONT RH |
Vehicle stopped |
0.00 km/h |
| Driving |
Almost same reading as speedometer (within ±10%) |
| WHEEL SENSOR FRONT LH |
Vehicle stopped |
0.00 km/h |
| Driving |
Almost same reading as speedometer (within ±10%) |
| WHEEL SENSOR REAR RH |
Vehicle stopped |
0.00 km/h |
| Driving |
Almost same reading as speedometer (within ±10%) |
| WHEEL SENSOR REAR LH |
Vehicle stopped |
0.00 km/h |
| Driving |
Almost same reading as speedometer (within ±10%) |
| VEHICLE SPEED |
Vehicle stopped |
0.00 km/h |
| Driving |
Almost same reading as speedometer (within ±10%) |
| ACTUAL GEAR POSITION |
D position |
D |
| R position |
R |
| N or P position |
N/P |
| BRAKE SWITCH |
Brake pedal is depressed. |
On |
| Brake pedal is not depressed. |
OFF |
| COMMAND WAKE UP SLEEP |
When command is not input from BCM |
SLEEP |
| When command is input from BCM |
WAKEUP |
| DOOR SWITCH (BACK DOOR) |
Back door closed |
CLOSE |
| Back door open |
OPEN |
| DOOR SWITCH (REAR RH) |
Rear RH door closed |
CLOSE |
| Rear RH door open |
OPEN |
| DOOR SWITCH (REAR LH) |
Rear LH door closed |
CLOSE |
| Rear LH door open |
OPEN |
| DOOR SWITCH (FRONT RH) |
Front RH door closed |
CLOSE |
| Front RH door open |
OPEN |
| DOOR SWITCH (FRONT LH) |
Front LH door closed |
CLOSE |
| Front LH door open |
OPEN |
| IGNITION SIGNAL |
Power switch ON |
ON |
| Power switch other than ON |
OFF |
| READY STATUS |
READY status |
On |
| Other than READY status |
Off |
| BACKUP UNIT DIAG RESULT |
Normal |
NORMAL |
| Overvoltage |
ERR1 |
| Communications malfunction |
ERR2 |
| Charging circuit malfunction |
ERR3 |
| Discharge circuit open |
ERR4 |
| Discharge circuit shorted |
ERR5 |
| Cell malfunction |
ERR6 |
| Backup power circuit malfunction |
ERR7 |
| Start signal malfunction |
ERR8 |
| The control part is in abnormal condition |
ERR9 |
| Monitor circuit malfunction |
ERR10 |
| Insulation malfunction |
ERR11 |
| Output circuit malfunction (other than discharge circuit) |
ERR12 |
| Temperature detection circuit malfunction |
ERR13 |
| Deteriorated |
ERR14 |
| Outside the reference voltage |
ERR15 |
| BACKUP UNIT MODE |
Backup power supply mode is active |
On |
| Backup power supply mode is not activated |
Off |
| BACKUP UNIT CHARGE STATUS |
80% or less (backup power supply not possible) |
CHRG1 |
| 80 - 99%(backup power supply possible) |
CHRG2 |
| 100% (backup power supply possible) |
FULL |