Diagnosis Procedure
- SECURITY INDICATOR LAMP ACTIVE TEST
With CONSULT-III
Check "THEFT IND" in "ACTIVE TEST" mode with CONSULT-III.
Without CONSULT-III
- Disconnect BCM.
- Check voltage between BCM harness connector M18 terminal 23 and ground.VOLTAGE SPECIFICATION
Connector Terminals Condition Voltage (V) (Approx.) (+) (-) M18 23 Ground ON 0 OFF Battery voltage Courtesy of NISSAN MOTOR CO., U.S.A.
Is the inspection result normal?
YES: Security indicator lamp is OK.
No: GO TO 2
- SECURITY INDICATOR LAMP CHECK
Check security indicator lamp condition by performing the self-diagnosis test. Refer to "DIAGNOSIS DESCRIPTION ".
Is the inspection result normal?
YES: GO TO 3
No: Replace combination meter. Refer to "REMOVAL AND INSTALLATION ".
- CHECK HARNESS CONTINUITY
- Turn ignition switch OFF.
- Disconnect BCM and combination meter connector.
- Check continuity between BCM connector (A) M18 terminal 23 and combination meter harness connector (B) M24 terminal 35.
23 - 35: Continuity should exist.
- Check continuity between BCM connector (A) M18 terminal 23 and ground.
23 - Ground: Continuity should not exist.
Courtesy of NISSAN MOTOR CO., U.S.A.
Is the inspection result normal?
YES: Replace the BCM. Refer to "REMOVAL AND INSTALLATION ".
No: Repair or replace harness.