Repair Procedures: Installation
- Check that the shift lever is placed in the "N" position.
- Lightly tighten the inhibitor switch mounting bolts (B) after installing the inhibitor switch (A).
- Lightly tighten the Manual Control Lever mounting nut (A) after installing the Manual Control Lever (B).
- Align the hole (A) in the Manual Control Lever with the "N" position hole (B) of the inhibitor switch and then insert the inhibitor switch guide pin (SST No.: 09480-A3800).
- Tighten the bolts (B) after tightening the nut (A) with the specified torque.
Tightening Torque:
- 17.7 - 24.5 N.m (1.8 - 2.5 kgf.m, 13.0 - 18.1 lb-ft)
- 9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb-ft)
- Lightly tighten the nut (B) after connected the shift cable (C) in the Manual Control Lever (D).
- Push shift cable (C) lightly to "F" direction displayed to eliminate free play of shift cable.
- Tighten the nut (B) with the specified torque.
- Connect the inhibitor switch connector (A).
Tightening Torque:
9.8 - 13.7 N.m (1.0 - 1.4 kgf.m, 7.2 - 10.1 lb-ft)
- Remove the inhibitor switch guide pin (SST No.: 09480-A3800) from the hole.
- Install the battery and battery tray.
(Refer to Engine Electrical System - "BATTERY ")
- Install the ECM.
(Engine Control System - "ECM")
- Install the air cleaner and air duct.
(Refer to Engine Mechanical System - "AIR CLEANER ")
CAUTION:
- Check that operating surely at each range of the inhibitor switch corresponding to each position of shift lever.