Test Procedures
- Turn ignition on. Install scan tool to data link connector, and verify DTC P0446 is set. If DTC P0446 only is set, go to next step. If any other DTC is set, repair that DTC first. When repairs are completed, clear DTCs and verify EVAP system operation.
- Start engine and allow to idle. Check EVAP system vacuum hoses for leaks and clogs. If leak or clog is found, repair as necessary. When repairs are completed, clear DTCs and verify EVAP system operation. If no leak or no clog is found, go to next step.
- Turn ignition off. Disconnect canister close valve 2-pin connector. Turn ignition on. Measure voltage between ground and canister close valve connector terminal No. 1 (Pink wire). If battery voltage is present, go to next step. If battery voltage is not present, check OXYGEN SENSOR (15-amp) fuse. If fuse is okay, repair open in Pink wire between canister close valve and engine compartment junction block.
- Turn ignition off. Disconnect ECM connector C44-1 (A/T) or C45-3 (M/T). Using jumper wire, connect canister close valve harness connector terminal No. 2 (White wire) to ground. Measure resistance between ground and ECM C44-1 (A/T) connector terminal No. 35 (White wire) or C45-3 (M/T) connector terminal No. 5 (White wire). If resistance is one ohm or less, go to next step. If resistance is more than one ohm, repair open in White wire between canister close valve and ECM. When repairs are completed, clear DTCs and verify EVAP system operation.
- Turn ignition off. Ensure canister close valve and ECM connectors are disconnected. Check for continuity between ground and canister close valve connector terminal No. 2 (White wire). If continuity does not exist, go to next step. If continuity exists, repair short to ground in White wire between canister close valve and ECM. When repairs are completed, clear DTCs and verify EVAP system operation.
- Measure resistance between canister close valve connector terminals (component side). If resistance is about 25 ohms, verify ECM connectors are clean and tight. If ECM connectors are okay, replace ECM. If resistance is not about 25 ohms, replace canister close valve. When repairs are completed, clear DTCs and verify EVAP system operation.