DTC Troubleshooting Index
DTC TROUBLESHOOTING CHART
| DTC (Recirculation Indicator Blinks) | Detection Item | Page |
|---|---|---|
| 7 | An open in the air mix control motor circuit | (see DTC 7: AN OPEN IN THE AIR MIX CONTROL MOTOR CIRCUIT ) |
| 8 | A short in the air mix control motor circuit | (see DTC 8: A SHORT IN THE AIR MIX CONTROL MOTOR CIRCUIT ) |
| 9 | A problem in the air mix control linkage, door, or motor | (see DTC 9: A PROBLEM IN THE AIR MIX CONTROL LINKAGE, DOOR, OR MOTOR ) |
| 10 | A short or open in the mode control motor circuit | (see DTC 10: A SHORT OR OPEN IN THE MODE CONTROL MOTOR CIRCUIT ) |
| 11 | A problem in the mode control linkage, doors, or motor | (see DTC 11: A PROBLEM IN THE MODE CONTROL LINKAGE, DOORS, OR MOTOR ) |
| 12 | A problem in the blower motor circuit | (see DTC 12: A PROBLEM IN THE BLOWER MOTOR CIRCUIT ) |
| 13 | A problem in the EEPROM in the heater control panel; the control panel must be replaced | (see HEATER CONTROL PANEL REMOVAL AND INSTALLATION ) |
| 14 (With A/C) | An open in the evaporator temperature sensor circuit | (see DTC 14: AN OPEN IN THE EVAPORATOR TEMPERATURE SENSOR CIRCUIT ) |
| 15 (With A/C) | A short in the evaporator temperature sensor circuit | (see page DTC 15: A SHORT IN THE EVAPORATOR TEMPERATURE SENSOR CIRCUIT ) |
In case of multiple problems, the recirculation indicator will indicate only the DTC with the least number of blinks.