LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2000 >> Insight L3-1.0L Hybrid >> Repair and Diagnosis >> Heating and Air Conditioning >> Blower Motor >> Service and Repair >> Disassembly and Assembly

Disassembly and Assembly

Note these items when overhauling the blower unit:




- The recirculation control motor (A), the blower motor high relay (B), and the blower motor (C) can be replaced without removing the blower unit.
- Before reassembly, make sure that the recirculation control linkage and door move smoothly.
- After reassembly, make sure the recirculation control motor runs smoothly.