Actuator Testing
- Disconnect actuator cable from actuator rod. Disconnect actuator 4-pin connector. Connect terminal Brown/White wire to battery positive terminal and Brown/Black, Brown, and Black wires to ground. Connect vacuum pump to check valve. Apply vacuum to actuator. Actuator rod should retract fully into actuator.
- If rod retracts only partially or not at all, check for leaking vacuum line or defective solenoid. With voltage and vacuum still applied to actuator, try to pull actuator rod out by hand. You should not be able to pull actuator rod out. If rod can be pulled out, actuator is defective.
- Disconnect ground from Brown/Black wire. Actuator rod should return. If actuator rod does not return, and ventilation hose and filter are clear, solenoid valve assembly is defective.
NOTE:
When replacing a defective solenoid valve assembly, ensure new "O" rings are used at each solenoid.