Oil Cooler Flushing
- Allow fluid in Rotunda Cleaner (222-00001) to heat up for 15-30 minutes, before using. Install line adapters into transaxle cooler lines.
- Attach Blue line to transmission return line quick disconnect.
- Attach Clear line to transmission outlet line quick disconnect.
- Backflush transaxle cooling system for 10 minutes, then flush cooler in a forward, normal flow direction for an additional 10 minutes.
- Refill transaxle with appropriate fluid. See LUBRICATION .