All Power Windows Inoperative
Verify concern, operate all switches. Ensure battery is fully charged. Ensure windows are properly aligned. Check central junction box fuses No. 6 (5-amp), No. 8 (5-amp), No. 15 (5-amp), No. 18 (5-amp) and No. 20 (5-amp). Check battery junction box fuses No. 103 (50-amp), No. 110 (30-amp) and No. 601 (30-amp). Check for open or shorted supply circuits. Check for faulty Generic Electronic Module (GEM), battery saver relay, instrument panel fuse block, delayed accessory relay and master switch. If concern remains after inspection, perform self-diagnostics. See SELF-DIAGNOSTIC SYSTEM .