Test B: All Door Locks Inoperative
- Check the 30A DOOR LOCK fuse located in the interior fuse junction panel. Is the fuse OK? If yes, goto step 5 . If no, goto next step. See Fig 1 .
- Replace the 30A DOOR LOCK fuse. Inspect the fuse. Does the fuse fail again? If yes, goto next step. If no, goto step 5 .
- Turn key OFF. Locate and disconnect the interior fuse junction panel connector C2. See Fig 1 . Locate and disconnect the power door lock relay connector, left and right power door lock switch connectors, and left and right power key switch connectors. Measure the resistance of the White/Green wire between the interior fuse junction panel connector C2 and ground. Is the resistance greater than 10,000 ohms? If yes, goto next step. If no, service the White/Green wire.
- Turn key OFF. Disconnect the power door lock relay connector, left and right power door lock switch connectors, left and right power key lock switch connectors, and left and right power door lock actuator connectors. Measure the resistance between the power door lock relay connector wires (all wires except White/Green and Black) and ground. Are any resistances greater than 10,000 ohms? If yes, go to next step. If no, service the wire(s) in question.
- Turn key OFF. Reconnect the interior fuse junction panel connector C2. Disconnect the power door lock relay connector. Measure the voltage on the White/Green wire at the power door lock relay connector. Is the voltage greater than 10 volts? If yes, goto next step. If no, service the White/Green wire between the power door lock relay and interior fuse junction panel.
- Turn key OFF. Disconnect the power door lock relay connector. Measure the resistance of the Black wire between the power door lock relay connector and ground. Is the resistance less than 5 ohms? If yes, goto next step. If no, service the (Black) wire.
- Turn key OFF. Disconnect the right and left power door lock switch connectors and right and left power key lock switch connectors. Measure the voltage on the White/Green wire at each switch connector. Are the voltages greater than 10 volts? If yes, goto next step. If no, service the White/Green wire(s) between the switch in question and the interior fuse junction panel.
- Turn key OFF. Reconnect the power door lock relay. Remove the left and right power door lock switches and left and right power key lock switches. Leave connectors connected. Check for voltage at each switch, while moving the switch. See MEASURE POWER DOOR LOCK SWITCH VOLTAGE . Is the voltage for all switches within specifications? If yes, goto next step if no, replace the switch in question.
- Turn key OFF. Disconnect the left and right power door lock switch connectors, left and right power key lock switch connectors, left and right power door lock actuator connectors, and power door lock relay connector. Measure the resistance of the Green/Black wire between the power door lock relay connector and all switch connectors. Measure the resistance of the Green and Red wires between the power door lock relay connector and the power door lock actuator connectors. Are the resistances less than 5 ohms? If yes, goto next step. If no, service the wire(s) in question.
- Turn key OFF. Access the power door lock relay. Leave the connector connected. Check for voltage at power door lock relay connector as shown in the table below while moving the door lock switch. Is the voltage for each switch position within specifications? If yes, replace the front door latch that does not work. If no, replace the power door lock relay. See MEASURE POWER DOOR LOCK RELAY VOLTAGE .
NOTE:
A specified voltage of 12V can be between the range of 10-13V. A specified voltage of 2.6V can be between the range of 2-3V.
MEASURE POWER DOOR LOCK SWITCH VOLTAGE
| Switch | Position | Green/Black Wire |
|---|---|---|
| Left Power Door Lock | Lock | 12V |
| Left Power Door Lock | Unlock | 2.6V |
| Left Key Lock Cylinder | Lock | 12V |
| Left Key Lock Cylinder | Unlock | 2.6V |
| Right Power Door Lock | Lock | 12V |
| Right Power Door Lock | Unlock | 2.6V |
| Right Key Lock Cylinder | Lock | 12V |
| Right Key Lock Cylinder | Unlock | 2.6V |
MEASURE POWER DOOR LOCK RELAY VOLTAGE
| Switch Position | Green Wire | Red Wire |
|---|---|---|
| Unlock | 0V | 12V |
| Lock | 12V | 0V |