Test KD - Canister Purge (CANP)
NOTE:
Perform this test when Service Code 85 is displayed during QUICK TESTS or when directed here by other test procedures. This test is intended to diagnose only the following:
- CANP solenoid
- Harness circuits (CANP, VPWR)
- ECA
TEST PIN WIRE COLOR IDENTIFICATION
| Application (Test Pin No.) | Wire Color |
|---|---|
| Pins 31, 32, or 35 - CANP | Gray/Yellow |
| Pins 37 or 57 - VPWR | Red |
- 1) Check System Function Enter Output State Check. See OUTPUT STATE CHECK under ADDITIONAL SYSTEM FUNCTIONS. Use only VOM or DVOM, not diagnostic tester, for this step. Turn key off and wait 10 seconds. Set DVOM on 20-volt scale. Connect DVOM negative test lead to STO and positive test lead to positive battery terminal. Using jumper wire, connect STI circuit to SIG RTN at Self-Test connector. Perform KOEO SELF-TEST until end of Continuous Memory Codes (DVOM reads zero volts). Depress and release throttle. DVOM should change to a high voltage reading. If reading did not change, depress throttle to WOT and release. If STO voltage does not increase, go to TEST QC, step 1. Leave test equipment hooked up. If reading changed, remain in Output State Check and go to next step.
- 2) Check CANP Solenoid Electrical Function With KOEO, set DVOM on 20-volt scale. Disconnect CANP solenoid. Connect DVOM positive test lead to VPWR circuit and negative test lead to CANP output circuit on harness connector. While observing DVOM, depress and release throttle several times to cycle output on and off. If CANP circuit does not cycle on and off, remove jumper wire and go to step 6. If CANP circuit cycles, go to next step.
- 3) Check Solenoid For Vacuum Leaks Turn key on. Leave CANP solenoid disconnected. Disconnect vacuum hose at CANP solenoid from manifold vacuum side of solenoid. Apply 16 in. Hg vacuum to manifold vacuum side of CANP solenoid. If CANP solenoid does not hold vacuum for 20 seconds, replace solenoid and repeat QUICK TEST PROCEDURES . If fault is still present, service fuel evaporation canister. If CANP holds vacuum for 20 seconds, leave vacuum pump attached and go to next step.
- 4) Check Solenoid Mechanical Operation While still in Output State Check, cycle CANP circuit off (no voltage). Reconnect CANP solenoid connector. Apply 16 in. Hg vacuum to CANP solenoid as in step 3. Depress and release throttle. If vacuum is released, check hose from CANP solenoid to canister for leaks or cracks. If okay, remove jumper wire from STI to SIG RTN and go to next step. If vacuum is not released, check hose from CANP solenoid to canister for leaks or cracks, if hose is okay, replace CANP solenoid. Repeat QUICK TEST PROCEDURES .
- 5) Check Vacuum Supply to CANP Solenoid Disconnect vacuum hose from CANP solenoid on manifold vacuum (PCV) side. Start engine. If vacuum is present at vacuum hose, EEC system is okay. Check evaporative canister. If vacuum is not present at hose, check vacuum hose for proper routing, kinks, or blockage, If hose is okay, check engine for cause of low vacuum.
- 6) Measure CANP Solenoid Resistance
Code 85 indicates a fault in the CANP solenoid circuit. Possible causes for this fault are:
- Faulty CANP solenoid
- Open in harness circuit
- Shorted harness circuit (power to ground)
Turn key off and wait 10 seconds. Set DVOM on 200-ohm scale. Disconnect CANP solenoid connector and measure CANP solenoid resistance. If resistance is 40-90 ohms, go to next step. If reading is incorrect, replace CANP solenoid and repeat QUICK TEST PROCEDURES .
- 7) Check Voltage of VPWR Circuit With KOEO, and CANP solenoid disconnected, set DVOM on 20-volt scale. Measure voltage between VPWR circuit at CANP solenoid harness connector and battery negative terminal. If reading is 10.5 volts or greater, go to next step. If reading is less than 10.5 volts, repair open in circuit and repeat QUICK TEST PROCEDURES .
- 8) Check Continuity of CANP Circuit Turn key off and wait 10 seconds. Disconnect CANP solenoid and ECA 60-pin connector. Inspect connector for damaged pins, corrosion, or loose wires. Repair if necessary. Connect breakout box, leaving ECA disconnected. Set DVOM on 200-ohm scale. Measure resistance between test pin No. 31 (No. 35 for TBI, or No. 32 on PFI engines) and CANP harness connector. If reading is less than 5 ohms, go to next step. If reading is 5 ohms or more, repair open circuit, remove breakout box and reconnect components. Repeat QUICK TEST PROCEDURES .
- 9) Check CANP Circuit For Short to Ground Turn key off and wait 10 seconds. Install breakout box, leaving ECA disconnected. Set DVOM on 200-k/ohm scale and disconnect CANP solenoid. Measure resistance between test pin No. 31 (No. 35 for TBI, No. 32 for PFI engines) and test pins No. 40, 46, and 60. If all readings are 10 k/ohms or more, go to next step. If any reading is less than 10 k/ohms, repair short to ground. Remove breakout box, reconnect components and repeat QUICK TEST PROCEDURES .
- 10) Check CANP Circuit For Short to Power
Turn key off and wait 10 seconds. Disconnect CANP solenoid. Install breakout box, leaving ECA disconnected. Set DVOM on 200-k/ohm scale and disconnect CANP solenoid. Measure resistance between test pin No. 31 (No. 35 for TBI, No. 32 for PFI engines) and test pins No. 37 and 57. If all reading are 10 k/ohms or more, remove breakout box. Replace ECA and repeat QUICK TEST PROCEDURES . If any reading is less than 10 k/ohms, repair short to power, remove breakout box and reconnect components. Repeat QUICK TEST. If any resistance is greater than 10 k/ohms, replace ECA. Remove breakout box and reconnect components. Repeat QUICK TEST.NOTE: A break in step numbering sequence occurs at this point. Procedure skips from step 10 to step 15. No test procedures have been omitted.
- 15) Check If CANP Caused Codes 16 or 26 With key off, disconnect vacuum hose at CANP solenoid on canister side. Start engine and allow to idle. If vacuum is present on canister side of CANP solenoid, go to step 1, in this test. If vacuum is not present, and a Code 26 is displayed, check for vacuum leaks or lack of vacuum. If Code 16 is present, check for vacuum leaks at injector "O" rings, vacuum lines and fittings, or between air meter and throttle body. Service as necessary and rerun QUICK TEST PROCEDURES .