LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 1990 >> Bronco II RWD, Standard, M5OD-R1 >> Repair and Diagnosis >> Electrical >> Charging Systems >> Alternator - Models W/Integral Regulator >> Circuit Testing >> "S" & "I" Circuit

"S" & "I" Circuit

  1. Remove wiring plug from regulator. Install jumper wire from regulator "A" terminal to wiring plug "A" terminal. Install jumper wire from regulator "F" terminal to rear of alternator housing.
  2. Connect voltmeter negative lead to battery negative terminal. Start engine and connect voltmeter positive lead to regulator "S" terminal and then to the "I" terminal. Note reading at each location. See Fig 1 .
    Fig 1: Testing "S" & "I" Circuit
    G50C01996Courtesy of FORD MOTOR CO.
  3. If voltage reading of terminal "S" is approximately 1/2 of the "I" terminal voltage, replace regulator. If voltage is not present, repair wiring.