Test Preparation
Before starting diagnostic procedure, verify that fuel tank(s) contain at least half a tank of fuel. Visually inspect fuel lines for obvious problems such as kinked hoses, damaged lines or push-to-connect fittings.
Hard starting, excessive White smoke, poor idle quality, or lack of power under load may be caused by several conditions. One of these conditions is air leaks in the fuel supply system. To perform fuel system air leak diagnosis, the following adapters need to be fabricated. See Fig 1.