LEMON Manuals: Even more car manuals for everyone
Home >> Eagle >> 1993 >> Vision TSi >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes - 3.3L/3.5L >> Fault Code Tests >> Test FC-29A - EVAP Purge Solenoid Control Circuit (DTC 31)

Test FC-29A - EVAP Purge Solenoid Control Circuit (DTC 31)

NOTE: For connector terminal identification, see CONNECTOR IDENTIFICATION . For appropriate wiring diagram, see WIRING DIAGRAMS  at end of article.
  1. Using DRB-II, erase faults. Actuate EVAP purge solenoid. Read faults. If DRB-II displays EVAP PURGE SOLENOID CONTROL CIRCUIT, go to step 6). If DRB-II does not display EVAP PURGE SOLENOID CONTROL CIRCUIT, go to next step.
  2. At this time, the condition required to set fault is not present. EVAP PURGE SOLENOID CONTROL CIRCUIT fault sets if solenoid is not in its proper state when monitored by Powertrain Control Module (PCM). Possible causes are: open or shorted EVAP purge control solenoid, open or shorted EVAP purge control circuit, failed PCM, or open ignition 12-volt feed to solenoid.
  3. Inspect wiring and connectors. Repair as required. Perform TEST VER-2. If wiring and connectors are okay, go to next step.
  4. Using DRB-II, read faults. With actuator test still running, wiggle wiring harness from solenoid to PCM. If EVAP PURGE SOLENOID CONTROL CIRCUIT fault returns, repair wiring where wiggling caused problem to appear. Perform TEST VER-2.
  5. If EVAP PURGE SOLENOID CONTROL CIRCUIT fault did not return, see INACTIVE FAULT CONDITION . Perform TEST VER-2.
  6. If DRB-II displayed EVAP PURGE SOLENOID CONTROL CIRCUIT in step 1), turn ignition off. Disconnect EVAP purge solenoid control valve connector. Turn ignition on. Place DRB-II in voltmeter mode.
  7. Using DRB-II, check voltage of EVAP purge solenoid control valve connector ignition 12-volt feed wire (Light Green/Black wire). If voltage is less than 10 volts, go to TEST FC-29B. If voltage is more than 10 volts, turn ignition off.
  8. Disconnect PCM connector. Using an external ohmmeter, check resistance of EVAP purge solenoid control wire (Pink/Black wire) between PCM connector terminal No. 52 and EVAP purge solenoid control valve connector.
  9. If resistance is more than 5 ohms, repair open EVAP purge solenoid control wire. Perform TEST VER-2. If resistance is less than 5 ohms, place DRB-II in ohmmeter mode. Using DRB-II, check resistance of PCM connector terminal No. 52, EVAP purge solenoid control wire (Pink/Black wire).
  10. If resistance is less than 5 ohms, repair EVAP purge solenoid control wire for short to ground. Perform TEST VER-2. If resistance is more than 5 ohms, reconnect EVAP purge solenoid control valve connector. Turn ignition on. Place DRB-II in voltmeter mode.
  11. Using DRB-II, check voltage of PCM connector terminal No. 52, EVAP purge solenoid control wire (Pink/Black wire). If voltage is less than 10 volts, replace EVAP purge solenoid control valve. Perform TEST VER-2. If voltage is more than 10 volts, replace PCM. Perform TEST VER-2.