Air Bag, Passenger: Removal
To avoid serious or fatal injury on vehicles equipped with airbags, disable the Supplemental Restraint System (SRS) before attempting any steering wheel, steering column, airbags, airbag curtains, knee blocker, seat belt tensioner, impact sensor or instrument panel component diagnosis or service. Disconnect the Intelligent Battery Sensor (IBS)/negative battery cable assembly from the negative battery post, then wait two minutes for the system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the SRS. Failure to take the proper precautions could result in accidental airbag deployment.
To avoid serious or fatal injury when removing a deployed airbag, rubber gloves, eye protection, and a long-sleeved shirt should be worn. There may be deposits on the airbag unit and other interior surfaces. In large doses, these deposits may cause irritation to the skin and eyes.
The following procedure is for replacement of an ineffective or damaged Passenger Airbag (PAB). If the airbag is ineffective or damaged, but not deployed, review the recommended procedures for Handling Non-Deployed Supplemental Restraints. Refer to HANDLING NON-DEPLOYED SUPPLEMENTAL RESTRAINTS . If the PAB has been deployed, review the recommended procedures for Service After A Supplemental Restraint Deployment before removing the airbag from the vehicle. Refer to SERVICE AFTER A SUPPLEMENTAL RESTRAINT SYSTEM DEPLOYMENT .
- Disconnect and isolate the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), disconnect the IBS connector first before disconnecting the negative battery cable. Wait two minutes for the system capacitor to discharge before further service.
- Remove the PAB and the instrument panel from the vehicle as a unit. Refer to PANEL, INSTRUMENT, REMOVAL .
- Place the instrument panel and PAB unit on a suitable work surface with the top cover facing down.NOTE:
If the instrument panel top cover will be reused, be certain to take the proper precautions to prevent the top cover from receiving cosmetic damage during the following procedures.
- Disconnect the two instrument panel wire harness connectors (2) from the PAB inflator connector receptacles. These wire connector insulators are secured by an integral Connector Position Assurance (CPA) lock to the inflator connector receptacles. Pull the lock straight back from the connector insulator, then pull the insulator straight out from the connector receptacle to disengage and disconnect it.
- Disengage the routing clip (1) of the instrument panel wire harness take out for the PAB from the tab on the outboard side of the PAB mounting bracket.
- Remove the two screws (5) that secure the PAB bracket to the instrument panel structural support.
- Remove the top cover and PAB unit from the instrument panel. Refer to COVER, INSTRUMENT PANEL, REMOVAL .
- Disengage each of the hooks on one side of the PAB housing (4) from the windows in the forward or rearward vertical walls of the PAB retainer or chute (3) on the underside of the top cover. To disengage the hooks, use hand pressure to pull the adjacent edge of the PAB housing firmly and evenly upward out of the retainer receptacle, while at the same time pulling the upper edge of the receptacle wall outward far enough to disengage the hooks.
- With all of the hooks on one side of the PAB housing disengaged from the retainer, rotate that side of the housing upward far enough to disengage the hooks on the opposite side of the housing from the retainer.
- With all of the hooks disengaged, lift the PAB housing, inflator and cushion as a unit from the receptacle of the PAB retainer or chute on the underside of the instrument panel top cover.