All Doors Failing To Lock From Any Switch
NOTE:
This testing only applies to models with vehicle theft security system.
Possible Causes:
- Driver Door Ajar
- Door Unlock Driver Circuit Shorted To Voltage
- Door Lock Driver Circuit Shorted To Ground
- Central Timer Module
Testing
- Ensure driver's side door is fully closed. Using scan tool, read DR DOOR AJAR SW status. If scan tool displays DR DOOR AJAR SW: CLOSED, perform SHORTED DRIVER'S SIDE DOOR AJAR CIRCUIT test under DOOR AJAR SYSTEM. If scan tool does not display DR DOOR AJAR SW: CLOSED, go to next step.
- Turn ignition off. Disconnect Central Timer Module (CTM) connector C2. Turn ignition on. Measure voltage between terminal No. 13 (Pink/Violet wire) and ground at CTM connector C2. See Figure . If voltage is more than one volt, repair short to voltage in Pink/Violet wire. If voltage is less than one volt, leave CTM connector C2 disconnected and go to next step.
- Turn ignition off. Using a DVOM, measure resistance between ground and terminal No. 13 (Pink/Violet wire) at CTM connector C2. If resistance is less than 100 ohms, repair short to ground in Pink/Violet wire. If resistance is more than 100 ohms, replace CTM.