Valve Guide Servicing
- Check valve stem-to-guide clearance. If clearance exceeds service limit (0.004" for intake; 0.006" for exhaust), replace with next oversize component. Valve stem-to-guide clearance can be obtained from the difference between ID of the guide and OD of valve stem. Guides are available in the following over-sizes:VALVE GUIDE OVERSIZE
Size Mark(1) Oversize In. (mm) Cyl. Head Hole Size In. (mm) 5 002 (.05) 5138-.5145 (13.050-13.0683) 25 010 (.25) 5216-.5224 (13.2486-13.2689) 50 020 (.50) 5315-.5323 (13.5001-13.5204) (1) Intake and exhaust guides. - Heat cylinder head to approximately 482°F. Using suitable valve guide tool, drive or hammer out each guide toward combustion chamber. Ream guide hole to specified size at normal temperature.
- To install, heat head to approximately 482°F. Insert guides and quickly drive into head. Remove any burrs on lower end of guides. Guide should protrude 0.539 - 0.563" above head (see Fig 2). Check ID and ream if necessary.