LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2002 >> Neon LE, Automatic >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Manual A/C-Heater Systems >> Specifications

Manual A/C-Heater Systems: Specifications

WARNING: Vehicle is equipped with Supplemental Inflatable Restraint (SIR) system. When servicing vehicle, use care to avoid accidental air bag deployment. SIR system-related components are located in various locations throughout interior and exterior of vehicle, depending on application. Do not use electrical test equipment on or near these circuits. If necessary, deactivate SIR system before servicing components. See appropriate AIR BAG RESTRAINT SYSTEMS article in RESTRAINTS.
SPECIFICATIONS

Application Specification
Compressor Type
Automatic Transmission Nippondenso 10S17
Manual Transmission Nippondenso 10S15
Compressor Belt Tension (1)
System Oil Capacity (2) 6.1 ozs.
Refrigerant Capacity 30 ozs.
System Operating Pressures (3)
High Side 150 psi (10.6 kg/cm2 )
Low Side 35 psi (2.5 kg/cm2 )
(1) Belt tension is maintained by automatic belt tensioner.
(2) Use ND-8 PAG refrigerant oil.
(3) With ambient temperature at 80° F (27°C).