Talon Turbo
- Remove purge control valve from vehicle. Identify hose connections for reassembly. See Fig 1. Connect a hand-held vacuum pump to vacuum nipple on purge control valve. See Fig 1. Apply 16 in. Hg vacuum to purge control valve.
- Lightly blow air in purge control valve from evaporative emission canister side. With vacuum 8 in. Hg or more, air should pass through purge control solenoid. With no vacuum applied to purge control valve, no air should pass through purge control valve. If airflow is as specified, go to next step. If airflow is not as specified, replace purge control valve.
- Connect a hand-held vacuum pump to positive pressure nipple on purge control valve. See Fig 1. Apply 16 in. Hg vacuum to purge control valve positive pressure nipple. If vacuum holds, purge control valve is okay. If vacuum does not hold, replace purge control valve.
Courtesy of CHRYSLER CORP.