System Precautions
CAUTION:
See ANTI-LOCK BRAKE SAFETY PRECAUTIONS
article in GENERAL INFORMATION.
Before proceeding with diagnosis, observe the following precautions:
- Ensure vehicle has a fully charged battery and functional charging system.
- Probe Controller Anti-Lock Brake (CAB) connector from pin side. DO NOT backprobe CAB connector. When probing connector cavity, be careful not to spread terminal. This could cause an intermittent problem.
- DO NOT cause short circuits when performing electrical tests. This will set additional fault messages, making diagnosis of original problem more difficult.
- DO NOT plug or unplug CAB connector with ignition on.
- Use DRB-II voltmeter unless instructed to use "external" voltmeter. DO NOT use test light in place of voltmeter.
- Use DRB-II ohmmeter unless instructed to use "external" ohm-meter.
- Always perform TEST VER-1A after repairs are made.
- Always disconnect DRB-II after use.
- Always disconnect DRB-II before charging battery.
- DO NOT disassemble any component designated as non-serviceable.