Diagnostic Procedures
- Perform powertrain diagnostic system check. See POWERTRAIN DIAGNOSTIC SYSTEM CHECK (GASOLINE) under SELF-DIAGNOSTIC SYSTEM. After performing powertrain diagnostic system check, go to next step.
- Turn ignition on, engine off. Install scan tool. If any component DTCs are set, see DIAGNOSTIC TROUBLE CODE DEFINITIONS . If no component DTCs are set, go to next step.
- Start engine. Idle engine at normal operating temperature. Operate vehicle within code enable criteria. If scan tool indicates DTC failed this ignition cycle, go to next step. If scan tool does not indicate DTC failed this ignition cycle, see DIAGNOSTIC AIDS .
- Turn ignition off. Inspect the following conditions:
- Check O2S1 is securely installed.
- Inspect for corrosion on terminals.
- Inspect for terminal tension at O2S1 electrical connector and PCM electrical connector.
- Inspect O2S1 ground circuit for a good connection.
- Inspect for any damaged wiring.
If problem was found, repair as necessary. After repairs, go to step 17 . If problem was not found, go to next step.
- Start engine. Inspect exhaust manifold for an exhaust leak near engine. If a problem is found, repair as necessary. After repairs, go to step 17 . If problem was not found, go to next step.
- Turn ignition off. Disconnect O2S1 electrical connector at sensor. Turn ignition on, engine off. If scan tool indicates O2S1 voltage is 351-551 millivolts, go to next step. If scan tool does not indicate O2S1 voltage is 351-551 millivolts, go to step 10 .
- Connect jumper wire between O2S1 connector (Purple wire), on PCM side and ground. If scan tool indicates O2S1 voltage is less than 20 millivolts, go to next step. If scan tool does not indicate O2S1 voltage is less than 20 millivolts, go to step 11 .
- Check O2S1 sensor connector for poor connections. If problem was found, repair as necessary. After repairs, go to step 17 . If problem was not found, go to next step.
- Turn ignition off. Replace O2S1. See OXYGEN SENSOR in appropriate REMOVAL, OVERHAUL & INSTALLATION article. After repair, go to step 17 .
- Turn ignition off. Repair short to ground in Purple wire between O2S1 and PCM. After repair, go to step 17 .
- Remove jumper wire. Using DVOM, measure voltage between O2S1 connector (Purple wire) and ground. If O2S1 voltage is more than 407 millivolts, go to next step. If O2S1 voltage is not more than 407 millivolts, go to step 13 .
- Turn ignition off. Disconnect PCM electrical connectors. Measure resistance in Tan wire between O2S1 and PCM. If resistance is more than 5 ohms, repair as necessary. After repairs, go to step 17 . If resistance does not measure more than 5 ohms, go to step 14 .
- Turn ignition off. Disconnect PCM electrical connectors. Measure resistance of Purple wire between O2S1 and PCM. If resistance is more than 5 ohms, repair as necessary. After repairs, go to step 17 . If resistance does not measure more than 5 ohms, go to step 15 .
- Check Tan wire for poor connection at PCM. If problem was found, repair as necessary. After repairs, go to step 17 . If problem was not found, go to step 16 .
- Check Purple wire for poor connection at PCM. If problem was found, repair as necessary. After repairs, go to step 17 . If problem was not found, go to step 16 .
- Replace PCM. See POWERTRAIN CONTROL MODULE in appropriate REMOVAL, OVERHAUL & INSTALLATION article. After repairs, go to next step.
- Using scan tool, clear DTCs. Turn ignition off for 30 seconds. Start engine. Operate vehicle within code enable criteria. If DTC does not reset, go to next step.
- Using scan tool, observe stored information. If any DTCs are displayed that have not been diagnosed, see DIAGNOSTIC TROUBLE CODE DEFINITIONS .
WARNING:
Avoid contact with moving parts and hot surfaces while working around a running engine in order to prevent physical injury.
NOTE:
Determine and correct cause of contamination in order to prevent damage to replacement sensors.