Control Pressure Switch
WARNING: This page is about a different car, the 1990 Cadillac Allante. However, it is still accessible from the selected car via links, so may be relevant.
The control pressure switch, mounted on the hydraulic unit, monitors booster servo circuit pressure and provides a signal to the EBCM when boost pressure reaches approximately 400 psi (2,750 kPa). This input is used by the EBCM for verifying proper operation of the booster/master cylinder assembly. The control pressure switch is a serviceable component. A short harness and 2-pin connector are used to connect the control pressure switch to the sensor block.