Lighting Chart A-10: DTC L209 With L210 1601 Power Circuit Problem: Description
The combination of codes L210 and L209 indicates a problem with the power supply circuit 1601.
NOTE:
The following step numbers refer to circled numbers on diagnostic chart. See Fig 1
. For circuit identification, see Fig 2
.
- This checks for voltage supply on circuit 1401. If voltage is present, each code must be diagnosed separately.
- If the fuse is open, the circuit 1601 must be checked for a short to ground.
- If the fuse is OK, there is an open or short to ground in the voltage supply (circuit 2) to the fuse or an open in circuit 1601.