System Response: Notes
| BLOWER SPEED | AIR INLET DOOR POSITION | TEMPERATURE DOOR POSITION | MODE DOORS POSITION | DEFROSTER DOOR POSITION | COMPRESSOR | HTR-WATER SHUT-OFF VALVE | IS BLOWER DELAYED FOR ENGINE WATER WARMUP? | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| CONTROL LEVER SETTINGS | OFF | FIXED LOW 6.0V - HTR 5.5V - A/C |
OUTSIDE AIR | VARIES - RESPONSIVE TO SENSORS | FORCED TO HEATER | SEALED | DOESNT OPERATE | USUALLY OPEN - EXC. CLOSED AT MAX. A/C | YES(1) | ||
| VENT | FORCED TO MAX. A/C | FORCED TO A/C | DOOR WILL ASSUME "BLEED" POSITION AFTER 45 SECOND DELAY AND WILL DELIVER BLEED AIR TO W/S IF IN HEATER OR BI-LEVEL MODE | CLOSED | NO - BLOWER IS TURNED ON BY ORIDE SW. | ||||||
| LO | VARIES - RESPONSIVE TO SENSORS | EITHER HEATER OR A/C - DEPENDS ON PROGRAMMER POSITION (NO BI-LEVEL) | OPERATES ABOVE APPROX. 32° | USUALLY OPEN - EXC. CLOSED AT MAX. A/C POSITION OF PROGRAMMER | YES(1) | ||||||
| AUTO | VARIABLE BLOWER PROGRAM | ||||||||||
| HI | FIXED HI - 13.5 V | RECIRCULATE AIR WHEN PROGRAMMER IS AT MAX. A/C - OTHERWISE OUTSIDE AIR | |||||||||
| FOG | VARIABLE BLOWER PROGRAM | BI-LEVEL | OPEN | ||||||||
| ICE | FIXED HI - 13.5 V | FORCED TO HEATER | FULL OPEN TO W/S | NO - BLOWER-IS TURNED ON BY ORIDE SW. | |||||||
|
|||||||||||