SME Fault Code 21F04B (SI B61 28 17)
Publication date: 2017-06-01Reference number: SI B61 28 17
SME FAULT CODE 21F04B
TECHNICAL SERVICE BULLETIN
| BMW: | F15 PHEV (X5 xDrive40e); F30 PHEV (330e iPerformance); G30 PHEV (530e iPerformance); G12 PHEV (740e xDrive iPerformance) |
| GROUP: | General Electrical Systems |
SITUATION
One or several of the following check control messages (CCM) may be displayed:
- "Engine fault! Power loss" (CCM-ID: 29)
- "Powertrain malfunction!" (CCM-ID: 633)
- "Hybrid system malfunctioning!" (CCM-ID: 585)
CAUSE
A timing problem between the SME and the cell supervision circuit (CSC).
CORRECTION
Delete the fault memory and then reassess the vehicle.
PROCEDURE
For conditions that are similar to the situation described:
- Use ISTA to check for the following codes in the battery management electronics (SME) fault memory.
- 21F04B - High-voltage battery unit: Internal CAN bus between SME and cell supervision circuit, communication fault.
NOTE: The following fault code may also be entered in the fault memory of the SME:- 21F1F6 - High-voltage battery, switch contactors: Switch-off after a fault.
- Check if fault code 21F04B is stored in the SME, but NOT currently present,
OR:
If NO further fault codes regarding cell voltage plausibility are entered.
Are any of the above conditions present?
YES - ignore this erroneous fault code. Delete the fault memory and then reassess the vehicle
NO - go to step 3
- Check if the fault code 21F04B is entered in the SME and is currently present
OR:
If other fault codes regarding the cell voltage plausibility are entered:
Are any of the above conditions present?
YES - follow the instruction from the diagnosis
NO - ignore this erroneous fault code. Delete the fault memory and then reassess the vehicle
WARRANTY INFORMATION
This service information bulletin provides technical, diagnostic and/or repair-related information.
Eligible and Covered Work/Repairs
To submit a claim for a repair with a verified defect in materials or workmanship, including diagnosis, please following the established and applicable warranty policy and procedures together with the using corresponding defect code and labor operations provided in the KSD2.