SME Fault Code 21F0D2 (SI B61 10 17)
Publication date: 2017-03-01Reference number: SI B61 10 17
SME FAULT CODE 21F0D2
TECHNICAL SERVICE BULLETIN
| BMW: | I01 94Ah (i3 & i3 REx) |
| GROUP: | General Electrical Systems |
SITUATION
The following Check Control message (CCM) was displayed to the customer:
- "Drive. Check as soon as possible" (CCM ID: 49)
CAUSE
Erroneous fault or hardware defect in the safety box (S-Box).
CORRECTION
Clear fault memory or diagnose with ISTA.
PROCEDURE
For conditions that are similar to the situation described:
- Read out the fault memory of the vehicle with ISTA and check whether the following fault code is stored in the fault memory of the battery management electronics (SME):
- 21F0D2 - High-voltage battery unit, negative terminal: Switching contactor, contact stuck closedNOTE: The following fault code may also be entered:
- 21F153 - High-voltage battery, safety concept 2: Safety circuit to switch off the switch contactors, switch-off detected
Was fault code 21F0D2 stored in the SME memory?
YES - Go to Step 2.
NO - continue diagnosis with ISTA.
- 21F0D2 - High-voltage battery unit, negative terminal: Switching contactor, contact stuck closed
- Delete the fault memory and allow the vehicle to go to sleep.
- Read out the fault memory again.
Was the fault code 21F0D2 reentered?
YES - continue diagnosis with ISTA. In most cases ISTA will recommend an S-Box replacement.
NO - This is an erroneous fault and can be ignored.
NOTE: Work on a solution is currently in progress. When the solution is available, this service information bulletin will be updated accordingly.
WARRANTY INFORMATION
Covered under the terms of the BMW New Vehicle Limited Warranty for Passenger Cars and Light Trucks.
| Defect Code: | 6127050200 |
| Labor Operation: | Labor Allowance: | Description: |
|---|---|---|
| 00 00 006 | Refer to KSD2 | Performing "vehicle test" (with vehicle diagnosis system - checking faults) (Main work) |
| Or: | ||
| 00 00 556 | Refer to KSD2 | Performing "vehicle test" (with vehicle diagnosis system - checking faults) (Plus work) |
| And: | ||
| 61 25 910 | Refer to KSD2 | Recharging high-voltage battery unit (to high voltage charging unit) |
If you are using a Main labor code for another repair, use the Plus code labor operation 00 00 556 instead.
Refer to KSD2 for the corresponding flat rate unit (FRU) allowances.
Other Repairs
If other work is performed as a result of performing the ISTA diagnostics and related test plans:
- When covered under an applicable limited warranty, claim the control module-related and/or other repair work using the applicable defect code and labor operations in KSD2/AIR.