Structure and inner electrical connection

The pressure converter is connected via a two-pin plug connection.

The pressure converter is a proportional valve. The pressure converter is supplied with voltage from terminal 15N.

Fig 1: Pressure Converter And Wastegate Valve - Circuit Diagram
G09872911Courtesy of BMW OF NORTH AMERICA, INC.
Index Explanation
1 Pressure converter, wastegate valve 2
PIN REFERENCE

Pin Explanation
Kl. 15N Terminal 15, voltage supply
PWM Pulse-width modulated activation of pressure converter