Specifications & Drive Belt Routing: Specifications
COOLING SYSTEM SPECIFICATIONS
| Application | Specification | ||
|---|---|---|---|
| Coolant Replacement Interval | 36 Months | ||
| Coolant Capacity | |||
| M20 | 11.0 Qts. (10.5L) | ||
| M30 (Including Heater) | 12.7 Qts. (12.0L) | ||
| M30 (With Integrated Air Conditioner) | 13.2 Qts. (12.5L) | ||
| M42 & M44 (Including Heater) | 6.7 Qts. (6.5L) | ||
| M42 & M44 (With Integrated Air Conditioner) | 7 Qts. (6.7L) | ||
| M50 (Including Heater) | 11.1 Qts. (10.5L) | ||
| M50 (With Integrated Air Conditioner) | 11.6 Qts. (11.0L) | ||
| M54 | 8.9 Qts. (8.4L) | ||
| M52 (Including Heater) | 10.6 Qts. (10.0L) | ||
| N62 | 14.8 Qts. (14.0L) | ||
| S14 | 10.0 Qts. (9.5L) | ||
| S38 | 14 Qts. (13.3L) | ||
| S50 | 11.2 Qts. (10.75L) | ||
| S52 | 11.4 Qts. (10.8L) | ||
| S54 | 10.6 Qts. (10.0L) | ||
| S62 (With Latent Heat Accumulator) | 14.3 Qts. (13.5L) | ||
| S62 (Without Latent Heat Accumulator) | 12.7 Qts. (12.0L) | ||
| Fan Clutch | |||
| Fan On Temperature | |||
| M30 | 172-187° F (78-86° C) | ||
| S14, M20, M50, M52, S52 & M54 | 194° F (90° C) | ||
| S38 & S50 | 198° F (92° C) | ||
| M42 & M44 | 190-205° F (88-96° C) | ||
| S62 | 196-210° F (91-99° C) | ||
| Fan Off Temperature | |||
| S14 | 113° F (45° C) | ||
| M20, M30, M42, M44, M50, M52, S38, S50, S52, M54 & S62 | 140° F (60° C) | ||
| Pressure Relief Valve Opens | 26.1-30.5 psi (1.8-2.1 bar) | ||
| Test Pressure For Cooling System | |||
| M20, M30, M42, M44, M50, M52, M54, S14, S38, S50 & S52 | 14.5 psi (1 Bar) | ||
| M52, M54, N62, S62 & S54 | 21.8 psi (1.5 Bar) | ||
| Thermostat Opening Temperature (Stamped In Thermostat) | |||
| S38 & S62 | 174° F (79° C) | ||
| S14, S50, M30, M20 & M50 | 176° F (80° C) | ||
| M42, M52 & S52 | 198° F (92° C) | ||
| M44 | 203° F (95° C) | ||