Secondary Air Injection Solenoid Valve 2, Checking

Special tools and workshop equipment required 

Test requirements 

Test procedure 

-- Perform a preliminary check to verify the customers complaint. Refer to PRELIMINARY CHECK .

Start diagnosis 

-- Remove the engine covers. Refer to the appropriate Service Information.

Fig 1: Engine Cover -1- And -2-
GWWA10-11070Courtesy of AUDI OF AMERICA, LLC

-- Disconnect the Secondary Air Injection (AIR) Solenoid Valve 2 -N320- electrical harness connector -3-.

Fig 2: Installed Location: Secondary Air Injection Solenoid Valve And Intake Manifold Runner Control (IMRC) Valve -N316-
GWWA21-10366Courtesy of AUDI OF AMERICA, LLC

Checking internal resistance 

-- Using a Multimeter, check the Secondary Air Injection (AIR) Solenoid Valve 2 -N320- terminals 1 to 2 for resistance.

Specified value: 25 to 35 Ω (at Approx. 20° C).

If the specified value was Not obtained:

-- Replace the Secondary Air Injection (AIR) Solenoid Valve 2 -N320- : Refer to appropriate Service Information.

-- Go to Final procedures.

If the specified value was obtained:

Checking voltage supply 

Switch the ignition ON.

-- Using a Multimeter, check the Secondary Air Injection (AIR) Solenoid Valve 2 -N320- electrical connector terminal 1 to Ground (GND) for voltage.

Specified value: Battery voltage.

Switch the ignition OFF.

If the specified value was Not obtained:

-- Check the wiring from the Secondary Air Injection (AIR) Solenoid Valve 2 -N320- electrical connector terminal 1 to Fuse SA16 (on fuse panel A) for an open or short circuit.

-- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-- If necessary, repair the faulty wiring connection.

-- Repair the circuit and replace any open fuses.

-- Go to Final procedures.

If the specified value was obtained:

Checking wiring 

-- Remove the Engine Control Module -J623-. Refer to appropriate Service Information. Using a Multimeter, check the Secondary Air Injection (AIR) Solenoid Valve 2 -N320- electrical harness connector terminal 2 to the Engine Control Module -J623- electrical harness connector T94 terminal 28 for an open circuit.

Secondary Air Injection (AIR) Solenoid Valve 2 -N320- electrical harness connector terminal: Engine Control Module -J623- electrical connector T94 terminal:
2 28

Specified value: 1.5 Ω Max.

If the specified value was obtained:

-- Check the wiring for an open circuit.

-- Check the electrical harness connector for damage, corrosion, lose or broken terminals.

-- If necessary, repair the faulty wiring connection.

-- Go to Final procedures.

If the specified value was obtained:

-- Replace the Engine Control Module -J623-. Refer to appropriate Service Information.

Final procedures 

-- Reinstall the engine covers, if necessary. Refer to the appropriate Service Information.

-- After the repair work, the following work steps must be performed in the following sequence:

  1. Check the DTC memory. Refer to DIAGNOSTIC MODE 03 - READ DTC MEMORY .
  2. If necessary, erase the DTC memory. Refer to DIAGNOSTIC MODE 04 - ERASE DTC MEMORY .
  3. If the DTC memory was erased, generate readiness code. Refer to READINESS CODE .