LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2002 >> 3.2CL Base >> Repair and Diagnosis >> Accessories & Equipment >> Infotainment >> Navigation Systems >> Symptom Troubleshooting >> System Diagnosis Test >> Yaw Rate

Yaw Rate

"Offset" is reference voltage or standard within the rate sensor. It should indicate 1.500 to 3.500V with the vehicle stopped.

"Sensor" indicator the voltage output from the yaw rate sensor. It should indicate 1.500 to 3.500 V with the vehicle stopped.

A "Sensor" output voltage HIGHER than that of the "Offset" voltage indicates the vehicle is turning to the RIGHT.

A "Sensor" output voltage LOWER than that of the "Offset" voltage indicates the vehicle is turning to the LEFT.

With the vehicle stopped, sitting still with the engine idling, both the "Offset" and "Sensor" voltages should be within 0.01 V +/- of each other.

If not replace the Navigation unit.

Example:

NOTE: The vehicle is stopped, sitting still, with the engine idling.

Good Offset 2.517 V

Sensor 2.517 V (0.010 V +/- )

Bad Offset 2.517 V

Sensor 2.823 V

NOTE: Do not try to tune the yaw rate sensor unless instructed by American Honda.
Fig 1: Yaw Rate Screen
G01157324Courtesy of AMERICAN HONDA MOTOR CO., INC.