LEMON Manuals: Even more car manuals for everyone

Operating Conditions

Enable Criteria
  1. Connect LV Battery
  2. Battery voltage is between 9V to 16V
Failure Criteria The CAN signal fails to be verified
  1. EDS_OutPut_FR_0x1F8
  2. EDS_OutPut_RR_0x1F9
  3. IDB_STATUS_0x20D
Failure/Mature Time 100 ms
Pass Criteria checksum of message
  1. EDS_OutPut_FR_0x1F8 and
  2. EDS_OutPut_RR_0x1F9
  3. IDB_STATUS_0x20D is correctly received
Pass/De-mature Time 200 ms
Failure Aging 40 Ignition Cycles