LEMON Manuals: Even more car manuals for everyone

Battery / Charging System (Service Information): Generator: Inspection: Procedure

  1. INSPECT CHARGING SYSTEM WARNING LIGHT 
    1. Verify that the battery is fully charged.

      Refer to INSPECTION 

    2. Verify that the assembly condition of the drive belt is normal.

      Refer to INSPECTION

    3. Switch the ignition ON (engine off), verify that the charging system warning light illuminates.
      1. If it does not illuminate, inspect the charging system warning light and the wiring harness.
        • If the charging system warning light and the wiring harness are normal, inspect the ECM.

          Refer to PROCEDURE - Step 1

    4. Verify that the charging system warning light turns off after the engine is started.

      If the charging system warning light does not turn off, perform the DTC inspection, then perform troubleshooting according to the corresponding diagnostic procedure.

      Refer to ON-BOARD DIAGNOSTIC TEST

      Refer to DIAGNOSTIC TROUBLE CODE CHART

  2. INSPECT GENERATOR 
    1. Generator voltage inspection
      1. Verify that the battery is fully charged.

        Refer to INSPECTION 

      2. Verify that the assembly condition of the drive belt is normal.

        Refer to INSPECTION

      3. Turn off all electrical loads.
      4. Start the engine.
      5. Verify that the generator rotates smoothly without any noise while the engine is running.

        If there is any noise, find the cause and repair or replace the generator.

      6. Measure the voltage at each terminal using a tester.
        GTY494150Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

        If not as specified, find the cause and repair or replace the applicable part.

        Generator standard voltage [IG-ON]

        Terminal B1-1: B+

        Terminal C1-1: Approx. 1 V or less

        Terminal C1-2: Approx. 0 V

        Generator standard voltage [Idle, 20 °C (68 °F)]

        Terminal B1-1: 13 to 15 V

        Terminal C1-1: Approx. 3 to 8 V

        Terminal C1-2: Turn the electrical loads (such as headlights, blower motor, rear window defogger, brake lights) on and verify that the voltage reading increases.

    2. Generator current inspection

      HINT: 

      Since the charging current decreases rapidly after starting the engine, carry out the following procedure quickly, and read the maximum current value.

      1. Verify that the battery is fully charged.

        Refer to INSPECTION 

      2. Verify that the assembly condition of the drive belt is normal.

        Refer to INSPECTION

      3. Disconnect the negative battery cable.

        Refer to REMOVAL 

      4. Connect a tester, which can read 120 A or more, between generator terminal 1A and generator terminal 1A cable.
      5. Connect the negative battery cable.

        Refer to INSTALLATION 

      6. Turn off all electrical loads.
      7. Start the engine.
      8. Increase engine speed to 2, 500 rpm.

        HINT: 

        • When the electrical load on the vehicle is low, the specified current cannot be verified although the generator is normal. In this case, increase the electrical load (Leave the headlights turned on for a while, then discharge the battery, or use a similar method.) and recheck.
        • If the generator itself or the ambient temperature are too high, the specified current also cannot be verified. In this case, cool down the generator and recheck.
      9. With the electric loads such as headlights, blower motor, rear window defogger, brake lights turned on, verify that the current value increases.

        If the current value does not increase, replace the generator.

        Refer to REMOVAL 

        Generator generated current minimum value

        70% of the nominal output current (nominal output current: 100 A)

        [Ambient temperature 20 °C (68 °F), voltage 13.0 to 15.0 V, both engine and generator are hot]

  3. INSPECT GENERATOR INTERNAL PARTS 
    1. Rotor
      1. Measure the resistance between the slip rings using a ohmmeter.

        If not within specification, replace the rotor.

        Generator rotor resistance (between slip rings) [20 °C (68 °F)]

        1.9 to 2.2 ohms

        GTY494290Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      2. Verify that there is no continuity between the slip ring and core using a ohmmeter.

        If there is continuity, replace the rotor.

        GTY488559Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. Inspect the slip ring surface condition.

        If the slip ring surface is rough, use a lathe or fine sandpaper to make it smooth.

    2. Stator coil
      1. Verify that the continuity is as indicated in the table.
        GTY483713Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
        1. If there is any malfunction, replace the stator coil.
          GTY489565Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
          *a Continuity
          *b Terminal
      2. Verify that there is no continuity between the stator coil leads and core using a ohmmeter.
        GTY494291Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

        If there is continuity, replace the stator coil.

    3. Brush
      1. Inspect brushes for wear.

        If any brush is worn almost to or beyond the limit, replace all of the brushes.

        Generator brush length

        Standard: 22.5 mm (0.886 in.)

        Minimum: 5.0 mm (0.20 in.)

        GTY493703Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
        *a Minimum
        *b Standard
    4. Brush spring
      1. Measure the force of the brush spring using a spring pressure gauge.
      2. Read the spring pressure gauge at the brush tip projection of 2 mm (0.08 in.).

        If not within specification, replace the brush spring.

        GTY486219Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
        *a 2 mm (0.08 in.)

        Generator brush spring force

        Standard: 4.1 to 5.3 N (0.42 to 0.54 kgf, 1.0 to 1.1 lbf)

        Minimum: 1.7 N (0.17 kgf, 0.38 lbf)

    5. Rectifier (Using an analog circuit tester)
      1. Inspect for continuity of the diodes using an analog circuit tester.
        GTY491345Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

        If not as specified, replace the rectifier.

        Specification

        Analog circuit tester Continuity
        Negative Positive
        E P1, P2, P3, P4, P5, P6 Yes
        B No
        P1, P2, P3, P4, P5, P6 E No
        B Yes
    6. Rectifier (Using a digital circuit tester)
      1. Inspect for continuity of the diodes using a digital circuit tester.

        If not as specified, replace the rectifier.

        Specification

        Digital circuit tester Continuity
        Negative Positive
        E P1, P2, P3, P4, P5, P6 No
        B Yes
        P1, P2, P3, P4, P5, P6 E Yes
        B No
    7. Bearing
      1. Inspect for abnormal noise, looseness, and sticking.

        Replace the bearing if necessary.

        GTY488565Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002