Check For Intermittent Problems
- CHECK FOR INTERMITTENT PROBLEMS
HINT:
A momentary interruption (open circuit) in the connectors and/or wire harness between the sensors and ECUs can be detected using the ECU Data List function of the Tech stream.
- Turn the ignition switch off and connect the Techstream to the DLC3.
- Turn the ignition switch to ON. Follow the directions on the Techstream to display the Data List and select areas where momentary interruption should be monitored.
HINT:
- A momentary interruption (open circuit) cannot be detected for 3 seconds after the ignition switch is turned to ON (initial check).
- If the status remains on (error displayed), check the continuity between the ECU and the sensors, or between ECUs.
- The "Error" display on the Techstream remains on for 1 second after the harness signal changes from momentary interruption (open circuit) to normal condition.
ABS/VSC/TRC
ABS/VSC/TRC - DATA LISTTester Display Measurement Item/Range Normal Condition Diagnostic Note FR Speed Open FR speed sensor open detection/Error or Normal Error: Momentary interruption
Normal: Normal- FL Speed Open FL speed sensor open detection/Error or Normal Error: Momentary interruption
Normal: Normal- RR Speed Open RR speed sensor open detection/Error or Normal Error: Momentary interruption
Normal: Normal- RL Speed Open RL speed sensor open detection/Error or Normal Error: Momentary interruption
Normal: Normal- - While observing the screen, gently jiggle the connector or wire harness between the ECU and sensors, or between ECUs.
OK: Error display does not change.
HINT:
If the display changes, the connector and/or the wire harness has caused a momentary interruption of the circuit. Repair or replace the connector and/or wire harness because one of them is faulty.
- SYMPTOM SIMULATION
Refer to How to Proceed with Troubleshooting (See HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS ).