LEMON Manuals: Even more car manuals for everyone

Data List / Active Test

  1. READ DATA LIST 

    HINT:

    Using Techstream's Data List allows switch, sensor, actuator, and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.

    NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
    1. Warm up the engine.
    2. Turn the ignition switch off.
    3. Connect Techstream to the DLC3.
    4. Turn the ignition switch to ON and turn the Techstream on.
    5. Enter the following menus: Powertrain / Engine and ECT / Data List.
    6. Follow the instructions on the Techstream and read the Data List.

    ECM: 

    DATA LIST

    Tester Display Measurement Item/Range Normal Condition Diagnostic Note
    SPD (NC) Counter gear speed/
    Min.: 0 rpm
    Max.: 12,750 rpm
    3rd gear with shift lever on D (after warming up the engine): Intermediate shaft speed (NC) becomes close to the engine speed Data is displayed in increments of 50 rpm
    SPD (NT) Input turbine speed/
    Min.: 0 rpm
    Max.: 12,750 rpm
    • Lock-up ON (after warming up engine):

      Input turbine speed (NT) is equal to engine speed.

    • Lock-up OFF (idling with shift lever on N):
    Input turbine speed (NT) is nearly equal to engine speed.
    Data is displayed in increments of 50 rpm
    Neutral Position SW Signal PNP switch status/
    ON or OFF
    Shift lever is:
    On P or N: ON
    Not on P or N: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    Stop Light Switch Stop light switch status/
    ON or OFF
    • Brake pedal is depressed: ON
    • Brake pedal is released: OFF
    -
    Shift Status ECM gearshift command/
    1st, 2nd, 3rd, 4th or 5th
    Shift lever position is:
    • On L: 1st
    • On 2: 1st or 2nd
    • On 3: 1st, 2nd or 3rd
    • On 4: 1st, 2nd, 3rd or 4th
    • On D: 1st, 2nd, 3rd, 4th or 5th
    -
    Shift SW Status (P Range) PNP switch status/
    ON or OFF
    Shift lever is:
    On P: ON
    Not on P: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    Shift SW Status (R Range) PNP switch status/
    ON or OFF
    Shift lever is:
    On R: ON
    Not on R: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    Shift SW Status (N Range) PNP switch status/ ON or OFF Shift lever is:
    On N: ON
    Not on N: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    Shift SW Status (D Range) PNP switch status/ ON or OFF Shift lever is:
    On 4 or D: ON
    Not on 4 or D: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    Shift SW Status (4 Range) PNP switch status/
    ON or OFF
    Shift lever is:
    On 4: ON
    Not on 4: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    Shift SW Status (3 Range) PNP switch status/
    ON or OFF
    Shift lever is:
    On 3: ON
    Not on 3: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    Shift SW Status (2 Range) PNP switch status/
    ON or OFF
    Shift lever is:
    On 2 or L: ON
    Not on 2 or L: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    Shift SW Status (L Range) PNP switch status/
    ON or OFF
    Shift lever is:
    On L: ON
    Not on L: OFF
    When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect
    HINT:
    When failure still occurs even after adjusting these parts, refer to DTC P0705  (see )
    A/T Oil Temperature 1 ATF temperature sensor value/
    Min.: -40°C (-40°F)
    Max. :215°C (419°F)
    • After stall test: Approximately 80°C (176°F)
    • Equal to ambient temperature while engine is cold
    If value is -40°C (-40°F) or 150°C (302°F) or more, ATF temperature sensor circuit is open or short circuited
    AT Fluid Flex lock-up judder judgment/
    ON or OFF
    • Judder judgment occurs: ON
    • Judder judgment does not occur: OFF
    -
    Lock Up Lock-up status/
    ON or OFF
    • Lock-up: ON
    • Not in lock-up: OFF
    -
    DSL Solenoid Status Shift solenoid DSL status/
    ON or OFF
    Shift solenoid DSL is:
    • Operating: ON
    • Not operating: OFF
    -
    SLT Solenoid Status Shift solenoid SLT status/
    ON or OFF
    • Accelerator pedal is depressed: OFF
    • Accelerator pedal is released: ON
    -
  2. PERFORM ACTIVE TEST 

    HINT:

    Performing Techstream's Active Test allows relays, VSVs, actuators and other items to be operated without removing any parts. Performing the Active Test early in troubleshooting is one way to save time. The Data List can be displayed during the Active Test.

    1. Warm up the engine.
    2. Turn the ignition switch off.
    3. Connect Techstream to the DLC3.
    4. Turn the ignition switch to ON and turn the Techstream on.
    5. Enter the following menus: Powertrain / Engine and ECT / Active Test.
    6. Perform the Active Test.

    ECM: 

    ACTIVE TEST

    Tester Display Test Part Control Range Diagnostic Note
    Activate the Solenoid (SLT)* [Test Details]
    Operate shift solenoid SLT and raise line pressure
    [Vehicle Condition]
    • Vehicle stopped
    • IDL: ON

    HINT:
    OFF: Line pressure up (when Active Test "Activate the Solenoid (SLT)" is performed, ECM commands SLT solenoid to turn OFF)
    ON: No action (normal operation)
    ON / OFF -
    Activate the Solenoid (S4) [Test Details]
    Operate shift solenoid S4
    [Vehicle Condition]
    • Vehicle stopped
    • Shift lever P or N position
    ON / OFF -
    Activate the Lock Up [Test Details]
    Control shift solenoid DSL to set automatic transaxle to lock-up
    [Vehicle Condition]
    • Throttle valve opening amount: Less than 35%
    • Vehicle speed: 60 km/h (36 mph) or more
    ON / OFF Possible to check shift solenoid valve DSL operation
    Control the Shift Position [Test Details]
    Operate shift solenoid valve and set each shift lever position
    [Vehicle Condition]
    • IDL: ON
    • Vehicle speed: 50 km/h (31 mph) or less

    [Other information]
    • Press "→" button: Shift up
    • Press "←" button: Shift down
    1st/2nd/3rd/4th/5th Possible to check operation of shift solenoid valves
    Activate the Solenoid (SR) [Test Details]
    Operate shift solenoid SR
    [Vehicle Condition]
    • Vehicle stopped
    • Shift lever P or N position
    ON / OFF -
    Activate the Solenoid (DSL) [Test Details]
    Operate shift solenoid DSL
    [Vehicle Condition]
    • Vehicle stopped
    • Shift lever P or N position
    ON/OFF -
    Activate the Solenoid (SL1) [Test Details]
    Operate shift solenoid SL1
    [Vehicle Condition]
    • Vehicle stopped
    • Shift lever P or N position
    ON / OFF -
    Activate the Solenoid (SL2) [Test Details]
    Operate shift solenoid SL2
    [Vehicle Condition]
    • Vehicle stopped
    • Shift lever P or N position
    ON / OFF -
    Activate the Solenoid (SL3) [Test Details]
    Operate shift solenoid SL3
    [Vehicle Condition]
    • Vehicle stopped
    • Shift lever P or N position
    ON / OFF -

    HINT:

    *: "Activate the Solenoid (SLT)" in the Active Test is performed to check the line pressure changes by connecting SST to the automatic transaxle, which is used in the HYDRAULIC TEST (see HYDRAULIC TEST ) as well. Please note that the pressure values in the Active Test and HYDRAULIC TEST are different.