Inspection Procedure
- CHECK SKID CONTROL ECU CONNECTOR
- Check the ECU Connector's connecting condition.
OK: The connector is securely connected.
NG: CONNECT CONNECTOR CORRECTLY
OK: Go to Next Step
- Check the ECU Connector's connecting condition.
- INSPECT BATTERY
- Check the battery voltage.
Standard: 11 to 14 V
NG: INSPECT CHARGING SYSTEM
OK: Go to Next Step
- Check the battery voltage.
- CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - COMBINATION METER)
- Disconnect the skid control ECU connector.
- Disconnect the combination meter connector.
- Measure the resistance.
Standard
RESISTANCE SPECIFICATIONTester Connection Specified Condition S1-15 (INFR) - C9-35 Below 1 Ω S1-15 (INFR) - Body ground 10 kΩ or higher - Reconnect the combination meter connector.
- Reconnect the skid control ECU connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: Go to Next Step
- INSPECT COMBINATION METER ASSEMBLY
- Check the combination meter system. (See COMBINATION METER
).
OK: Combination meter is normal.
NG: REPLACE COMBINATION METER ASSEMBLY
OK: Go to Next Step
- Check the combination meter system. (See COMBINATION METER
).
- INSPECT SKID CONTROL ECU (CSW TERMINAL)
- Disconnect the skid control ECU connector.
- Ground terminal CSW of the skid control ECU.
Standard
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition S1-43 (CSW) - Body ground VSC OFF switch not pushed in 10 kΩ or higher - Reconnect the skid control ECU connector.
OK: REPLACE MASTER CYLINDER SOLENOID
NG: Go to Next Step
- INSPECT VSC OFF SWITCH
- Remove the VSC OFF switch.
- Disconnect the VSC OFF switch connector.
- Measure the resistance.
Standard
RESISTANCE SPECIFICATIONTester Connection Switch Condition Specified Condition T17-3-T17-4 Released 10 kΩ or higher T17-3-T17-4 Released Below 1 Ω - Reconnect the VSC OFF switch connector.
- Reinstall the VSC OFF switch.
NG: REPLACE VSC OFF SWITCH
OK: Go to Next Step
- CHECK HARNESS AND CONNECTOR (VSC OFF SWITCH CIRCUIT)
- Disconnect the skid control ECU connector.
- Disconnect the VSC OFF switch connector.
- Measure the resistance.
Standard
RESISTANCE SPECIFICATIONTester Connection Specified Condition S1-43 (CSW) - T17-3 Below 1 Ω S1-43 (CSW) - Body ground 10 kΩ or higher T17-4 - Body ground Below 1 Ω - Reconnect the VSC OFF switch connector.
- Reconnect the skid control ECU connector.
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: REPLACE MASTER CYLINDER SOLENOID