Inspection Procedure
WARNING: This page is about a different variant/trim than selected.
- CHECK HARNESS AND CONNECTOR (MULTI-DISPLAY CONTROLLER - MULTI-DISPLAY)
- Disconnect the multi-display connector M5 and multi-display controller connector R29.
- Measure the resistance according to the value(s) in the table below.
Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester connection Condition Specified condition SGD1 - SGN1 Always Below 1 Ω NTSC - NTS1 Always Below 1 Ω SGND - SLD3 Always Below 1 Ω NTS1 - Body ground Always 10 kΩ or higher SGN1 - Body ground Always 10 kΩ or higher SG33 - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to Next Step
- INSPECT MULTI-DISPLAY CONTROLLER (OUTPUT SIGNAL)
- Reconnect the multi-display controller connector R29.
- Measure the waveform according to the table below.
OK
TESTER CONNECTION SPECIFIED CONDITION CHARTTester connection Condition Specified condition NTSC - Body ground DVD display Is ON A waveform synchronized with display signals is output HINT:
The waveform pattern may differ from that shown in the illustration below due to differences in oscilloscope setting. A normal multi-display controller operating condition can be determined if any waveform is output.
- Oscilloscope waveform
- Terminal: NTSC - Body ground Setting: 500 mV/DIV 10 μs/DIV
Condition: DVD display is ON.
- Terminal: NTSC - Body ground Setting: 500 mV/DIV 10 μs/DIV
NG: REPLACE MULTI-DISPLAY CONTROLLER
OK: RETURN TO THE ORIGINAL INSPECTION FLOW BECAUSE THE CHECK RESULT IS NORMAL