Typical Malfunction Thresholds
Functional check:
TYPICAL MALFUNCTION THRESHOLDS
| Either of following conditions 1 or 2 met | - |
| 1. Frequency that following conditions (a) and (b) met | 5 times or more |
| (a) Engine RPM - target engine RPM (A/C OFF and NSW OFF) | Below -100 rpm, or 150 rpm or more |
| (b) ISC feedback correction amount | -0.17 L/sec or less, or 2.08 L/sec or more |
| 2. Frequency that following conditions (c) and (d) met | Once |
| (c) Engine RPM - target engine RPM (A/C OFF and NSW OFF) | Below -100 rpm, or 150 rpm or more |
| (d) ISC airflow rate (learning value) | 1.3 L/sec. or less, or 8.5 L/sec. or more |