LEMON Manuals: Even more car manuals for everyone

Throttle Body: Installation

  1. INSTALL THROTTLE BODY ASSEMBLY 
    1. Install a new throttle body gasket to the intake air connector.
      Fig 1: Installing Throttle Body Gasket To Intake Air Connector
      G04441436Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Install the throttle body assembly with the 4 bolts.

      Torque: 11 N*m (112 kgf*cm, 8 ft.*lbf) 

      Fig 2: Installing Throttle Body Assembly With Bolts
      G04441437Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Connect the fuel vapor feed hose (A).
    4. Connect the water bypass hose No.3 (B).
    5. Connect the water bypass hose No.2 (C).
    6. Connect the throttle motor connector (D).
    Fig 3: Connecting Fuel Vapor Feed Hose (A)
    G04441438Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSTALL AIR CLEANER CASE W/ RESONATOR 
    1. Install the air cleaner hose No.1 to the throttle body assembly with the hose clamp.
      Fig 4: Installing Air Cleaner Hose No.1 To Throttle Body Assembly With Hose Clamp
      G04441439Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Install the air cleaner case w/ resonator with the 5 bolts.

      Torque: 5.0 N*m (51 kgf*cm, 44 in.*lbf) 

      Fig 5: Installing Air Cleaner Case W/ Resonator With Bolts
      G04441440Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Connect the MAF meter connector.
    4. Connect the 2 wire harness clamps to the air cleaner.
      Fig 6: Connecting Wire Harness Clamps To Air Cleaner
      G04441441Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    5. Connect the ventilation hose No.2.
    Fig 7: Connecting Ventilation Hose No.2
    G04441442Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSTALL AIR CLEANER CAP W/ INLET 
    1. Install a new air cleaner element to the air cleaner case.
    2. Install the air cleaner cap w/ inlet with the 4 clamps.
    3. Install the air cleaner cap w/ inlet with the 2 bolts.

      Torque: 7.0 N*m (71 kgf*cm, 62 in.*lbf) 

    Fig 8: Installing Air Cleaner Cap W/ Inlet With Clamps And Bolts
    G04441443Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  4. ADD COOLANT (See  COOLANT  ) 
  5. CHECK FOR ENGINE COOLANT LEAKS (See  COOLING SYSTEM  ) 
  6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL 
  7. INSTALL ENGINE ROOM SIDE LH COVER (See step 118 in  INSTALLATION  ) 
  8. PERFORM INITIALIZATION 

    Some system need initialization when reconnecting the battery cable. INITIALIZATION