LEMON Manuals: Even more car manuals for everyone

Basic Inspection

  1. CHECK FLUID LEVEL 
    1. Using SST, create a short-circuit between terminals TC and CG of the DLC3.

      SST 09843-18040

    2. Start the engine and run at idle.
      • The A/C switch must be turned off.
      • On models with active height control suspension & adaptive variable suspension, turn the height control switch off.
    3. Slowly move the shift lever through all positions from P to L, and move it back to the P position.
      Fig 1: Identifying Connector DLC3
      G03059022Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    4. Switch to the fluid temperature detection mode.

      Move the shift lever from the N to the D position, or from D to N, within 1.5 seconds. (Repeat this operation for 6 seconds or more.)

      OK: The A/T OIL TEMP warning light comes on for 2 seconds and then goes off. 

    5. Return the shift lever to the P position and disconnect terminals TC and CG.
    6. Idle the engine to raise oil temperature.
    7. Lift up the vehicle immediately after the meter indicator light (ATF temperature warning light) comes on.
      • The A/T OIL TEMP warning light indicates the ATF temperature according to the following table.
        Fig 2: Identifying Display
        G03059023Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      AFT TEMPERATURE DESCRIPTION

      ATF Temp. Less than optimized temperature Optimized temperature More than optimized temperature
      A/T OIL TEMP warning light OFF ON Blinking
    8. Remove the overflow plug and check the fluid level.

      Standard: 

      AFT LEVEL DESCRIPTION

      When ATF overflows ATF level is higher than specification (Go to step k)
      When ATF does not overflow ATF level is equal to or lower than specification (Go to step i)

      HINT:

      • "Overflow" indicates the condition under which ATF drains out from the overflow tube.
      • The capacity of the overflow tube is approximately 3 cc. If the amount of drained ATF is little, only the fluid remaining in the tube has drained out. This condition is not considered as "overflow".
    9. Remove the refill plug.
    10. Add ATF through the refill hole until it flows out from the overflow hole.

      Fluid type: Toyota genuine ATF WS 

      • When the draining ATF has become a trickle, install the overflow plug with a new gasket.
      • Install the refill plug if removed.
      • Lower the vehicle.
      • Turn the ignition switch off to stop the engine.
  2. CHECK FLUID CONDITION 

    If the fluid smells burnt or is black, replace it (see step  6

    Fig 3: Locating Refill/Overflow Plug
    G03059024Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSPECT AND ADJUST SHIFT LEVER POSITION 
    1. When shifting the shift lever from the N position to other positions, check that the lever can be shifted smoothly and accurately to each position and that the position indicator comes on in accordance with the shift lever position.

      If the indicator and shift lever position do not match, carry out the following adjustment procedures.

      1. Remove the nut and disconnect the shift control cable from the control shaft lever.
      2. Move the control shaft fully rearward.
      3. Return the control shaft lever 2 notches to the N position.
      4. Set the shift lever to the N position.
      5. Connect the shift control cable and temporarily install the control shaft lever nut.
      6. While holding the shift lever lightly toward the R position side, tighten the control shaft lever nut.

        Torque: 14.5 N.m (148 kgf Cm, 11 ft. lbf) 

        Fig 4: Locating Control Shaft Lever
        G03059025Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      7. Start the engine and make sure that the vehicle moves forward when shifting the lever from the N to the D position and reverses when shifting it to the R position.
        Fig 5: Inspecting And Adjusting Park/Neutral Position
        G03059026Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  4. INSPECT AND ADJUST PARK/NEUTRAL POSITION 
    1. Check that the engine can be started when the shift lever is in the N or P position, but cannot be started in other positions.

      If operation cannot be done as stated above, carry out the following adjustment procedures.

      • Loosen the park/neutral position switch bolt and set the shift lever to the N position.
      • Align the groove with the neutral basic line.
      • Hold in position and tighten the bolt.

        Torque:13 N.m (130 kgf° Cm, 9 ft. lbf) 

    2. For continuity inspection of the park/neutral position switch, see CIRCUIT INSPECTION .
  5. CHECK IDLE SPEED 

    Idle speed (In N position and air conditioner OFF): 700 +/- 50 RPM 

  6. ADD AUTOMATIC TRANSMISSION FLUID 
    Fig 6: Add Automatic Transmission Fluid Chart
    G03059027Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. When adding maximum amount of fluid: [*1]
      1. Lift up the vehicle while keeping it level.
      2. Remove the refill plug and overflow plug.
        Fig 7: Removing Refill Plug And Overflow Plug
        G03059028Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. Add ATF through the refill hole until it drains out from the overflow hole.
        NOTE: Be sure to add Toyota genuine ATF WS.
        Fig 8: Adding ATF Through Refill Hole Until It Drains Out From Overflow Hole
        G03059029Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      4. Temporarily install the gasket and overflow plug.

        Torque: 20 N.m (204 kgf° Cm, 15 ft. lbf) 

      5. Add the proper amount of ATF through the refill hole.
        NOTE: Refill amount differs depending on the related procedures indicated below.
        REFILL PROCEDURE

        Related procedures Refill amount
        Removal and installation of oil pan 1.7 liters (1.8 us qts, 1.5 Imp Qts)
        Removal of transmission valve body assy 4.3 liters (4.5 us qts, 3.8 Imp Qts)
        Removal of torque converter assy 5.4 liters (5.7 us qts, 4.8 Imp Qts)
        Fig 9: Locating Overflow Plug
        G03059030Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      6. Temporarily install the O-ring and refill plug.

        Torque: 39 N.m (400 kgf° Cm, 29 ft. lbf) 

      7. Lower down the vehicle.
        Fig 10: Locating Refill Plug
        G03059031Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      8. Using SST, create a short-circuit between terminals TC and CG of the DLC3.

        SST 09843-18040

      9. Start the engine and run at idle.
        NOTE:
        • The A/C switch must be turned off.
        • On models with active height control suspension & adaptive variable suspension, turn the height control switch off.
      10. Slowly move the shift lever from the P to the 2-L position.

        Return the shift lever to the P position.

        Fig 11: Identifying Connector DLC3
        G03059032Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      11. Switch to the fluid temperature detection mode. Move the shift lever from the N to the D position, or from D to N, within 1.5 seconds. (Repeat this operation for 6 seconds or more.)

        OK: The A/T OIL TEMP warning light comes on for 2 seconds and then goes off. 

      12. Disconnect terminals TC and CG after confirming the above condition.
      13. Idle the engine to raise the fluid temperature.
        Fig 12: Identifying Display
        G03059033Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      14. Lift up the vehicle immediately after the meter indicator light (ATF Temperature Warning Light) comes on.
        NOTE:
        • Add fluid only when the meter indicator light is on.
        • Perform this procedure while the engine is idling.
          Fig 13: Fluid Temperature Specification
          G03059034Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      15. Remove the overflow plug. If ATF overflows, proceed to [*2].

        If ATF does not overflow, proceed to [*3].

        HINT:

        "Overflow" indicates the condition under which ATF drains out from the overflow tube.

        NOTE: Capacity of the overflow tube is approximately 3 cc.
        Fig 14: Locating Over Flow Plug
        G03059035Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. When fluid overflows: [*2]
      1. Install the overflow plug with a new gasket when the draining ATF has become a trickle.

        Torque: 20 N.m (204 kgf° Cm, 15 ft.lbf) 

      2. Install the refill plug with a new O-ring.

        Torque: 39 N.m (400 kgf° Cm, 29 ft.lbf) 

      3. Lower down the vehicle.
      4. Turn the ignition switch off and remove the SST.
      5. Check for fluid leaks in the transmission.

        If there are leaks, it is necessary to repair or replace O-rings, FIPGs, oil seals, plugs or other related parts.

        Fig 15: Draining ATF
        G03059036Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. When fluid does not overflow: [*3]
      1. Remove the refill plug.
        Fig 16: Removing Refill Plug
        G03059037Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      2. Add ATF through the refill hole until it drains out from the overflow hole.
        Fig 17: Adding ATF Through Refill Hole, Until It Drains Out From Overflow Hole
        G03059038Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. Install the overflow plug with a new gasket when the draining ATF has becomes a trickle.

        Torque: 20 N.m (204 kgf° Cm, 15 ft. lbf) 

      4. Install the refill plug with a new O-ring.

        Torque: 39 N.m (400 kgf° Cm, 29 ft. lbf) 

      5. Lower down the vehicle.
      6. Turn the ignition switch off.
      7. Check for fluid leaks in the transmission.

        If there are leaks, it is necessary to repair or replace O-rings, FIPGs, oil seals, plugs or other related parts.

        Fig 18: Draining ATF
        G03059039Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    4. When adding a minimum amount of fluid: [*4]
      1. Using SST, create a short-circuit between terminals TC and CG of the DLC3.

        SST 09843-18040

      2. Start the engine and run at idle.
        NOTE: The A/C switch must be turned off.
      3. Slowly move the shift lever from the P to the 2-L position. Return the shift lever to the P position.
        Fig 19: Identifying Connector DLC3
        G03059040Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      4. Switch to the fluid temperature detection mode. Move the shift lever from the N to the D position, or from D to N, within 1.5 seconds. (Repeat this operation for 6 seconds or more.)

        OK: The A/T OIL TEMP warning light comes on for 2 seconds and then goes off. 

      5. Disconnect terminals TC and CG after confirming the above condition.
      6. Idle the engine to raise the fluid temperature.
        Fig 20: Identifying Display
        G03059041Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      7. Lift up the vehicle immediately after the meter indicator light (ATF Temperature Warning Light) comes on.
        NOTE:
        • Add fluid only when the meter indicator light is on.
        • Perform this procedure while the engine is idling.
          Fig 21: Identifying Fluid Temperature Pattern
          G03059042Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      8. Remove the overflow plug. If ATF overflows, proceed to [*5]. If ATF does not overflow, proceed to [*6].

        HINT:

        "Overflow" indicates the condition under which ATF drains out from the overflow tube.

        Fig 22: Locating Overflow Plug
        G03059043Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    5. When fluid overflows: [*5]
      1. Install the overflow plug with a new gasket when the draining ATF has become a trickle.

        Torque: 20 N.m (204 kgf° Cm, 15 ft. lbf) 

      2. Install the refill plug with a new O-ring.

        Torque: 39 N.m (400 kgf° Cm, 29 ft. lbf) 

      3. Lower down the vehicle.
      4. Turn the ignition switch off.
      5. Check for fluid leaks in the transmission.

        If there are leaks, it is necessary to repair or replace O-rings, FIPGs, oil seals, plugs or other related parts.

        Fig 23: Draining ATF
        G03059044Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    6. When fluid does not overflow: [*6]
      1. Remove the refill plug.
        Fig 24: Removing Refill Plug
        G03059045Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      2. Add ATF through the refill hole until it drains out from the overflow hole.
        Fig 25: Adding ATF Through Refill Hole
        G03059046Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. Install the overflow plug with a new gasket when the draining ATF has become a trickle.

        Torque: 20 N.m (204 kgf° Cm, 15 ft. lbf) 

      4. Install the refill plug with a new O-ring.

        Torque: 39 N.m (400 kgf° Cm, 29 ft. lbf) 

      5. Lower down the vehicle.
      6. Turn the ignition switch off.
      7. Check for fluid leaks in the transmission.

        If there are leaks, it is necessary to repair or replace O-rings, FIPGs, oil seals, plugs or other related parts.

        Fig 26: Draining ATF
        G03059047Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002