Inspection Procedure
- Check fuse.
CHECK:
Measure the resistance of the IGN2 fuse and IGN1 fuse in the instrument panel J/B.
OK:
Below 1 Ω
CHECK:
Measure the resistance of the STA fuse in the engine room R/B.
OK:
Below 1 Ω
CHECK:
Measure the resistance of the ECU-B fuse and AM2 fuse in the engine room R/B.
OK:
Below 1 Ω
- NG: Inspect for short circuit in harness and all components connected to fuse.
- OK: Go to next step.
- Inspect combination meter (Power source).
PREPARATION:
Disconnect the combination meter connectors.
CHECK:
Measure the resistance according to the value(s) in the table below.
OK:
TERMINAL SPECIFIED CONDITION CHARTTerminal No Condition Specified condition C6-12 - Body ground Always Below 1 Ω Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
CHECK:
Measure the voltage according to the value(s) in the table below.
OK:
TERMINAL SPECIFIED CONDITION CHARTTerminal No Condition Specified condition C6-23 - Body ground Always 10 to 14 V C5-28 - Body ground Ignition switch ON 10 to 14 V C6-24 - Body ground Ignition switch ON 10 to 14 V C5-3 - Body ground Ignition switch ST 10 to 14 V Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- NG: Repair or replace harness or connector.
- OK: Replace combination meter (See HOW TO USE THE DIAGNOSTIC CHART AND INSPECTION PROCEDURE ).