LEMON Manuals: Even more car manuals for everyone

Power Steering Vane Pump: Inspection

NOTE: When using a vise, do not overtighten it.
  1. Check oil clearance between vane pump shaft and bushing  :

    Using a micrometer and caliper gauge, measure the oil clearance.

    Fig 1: Measuring Vane Pump Shaft To Bushing Oil Clearance
    G01026034Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Standard clearance: 0.03 - 0.05 mm (0.0012 - 0.0020 in.) 
    2. Maximum clearance: 0.07 mm (0.0028 in.) 

    If it is more than the maximum, replace the vane pump shaft and front housing.

  2. Inspect vane pump rotor and vane plates  :
    1. Using a micrometer, measure the height, thickness and length of the vane plates.
      Fig 2: Measuring Vane Plates
      G01026035Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      1. Minimum height: 8.6 mm (0.339 in.) 
      2. Minimum thickness: 1.397 mm (0.0550 in.) 
      3. Minimum length: 14.991 mm (0.5902 in.) 
    2. NOTE: There are 5 vane plate lengths with the following vane pump rotor and cam ring marks:
      Inscribed mark: 1, 2, 3, 4 or None 
      Fig 3: Locating Rotor & Cam Ring marks
      G01026038Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      Fig 4: Measuring Rotor Groove & Plate Clearance
      G01026036Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Using a feeler gauge, measure the clearance between the vane pump rotor groove and vane plate.
      1. Maximum clearance: 0.035 mm (0.0014 in.) 

        If it is more than the maximum, replace the vane plate and/or vane pump rotor with one having the same mark stamped on the cam ring.

        Fig 5: Rotor & Cam Ring Identification/Specifications Chart
        G01026037Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. Inspect flow control valve  :
    1. Coat the flow control valve with power steering fluid and check that it falls smoothly into the flow control valve hole by its own weight.
      Fig 6: Inspecting Flow Control Valve
      G01026039Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the flow control valve for leakage. Close one of the holes and apply 392 - 490 kPa (4 - 5 kgf/cm2 , 57 - 71 psi) of compressed air into the opposite side hole, and confirm that air does not come out from the end hole.
      Fig 7: Testing Flow Control Valve
      G01026040Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    If necessary, replace the flow control valve with one having the same letter as inscribed on the front housing.

    1. Inscribed mark: A, B, C, D, E or F 
      Fig 8: Locating Flow Control Valve Marks
      G01026041Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

  4. Inspect spring  :

    Using vernier calipers, measure the free length of the spring.

    Fig 9: Measuring Flow Control Valve Spring Length
    G01026042Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Minimum free length: 33.2 mm (1.307 in.) 

    If it is not within specification, replace the spring.