Compressor Lock Sensor
Disconnect compressor clutch connector. Using ohmmeter, measure resistance between compressor clutch connector terminals No. 1 and 2. See Figure. On 2000 models, resistance should be 570-1050 ohms at 68°F (20°C). On 2001 models, resistance should be 990-1210 ohms at 68°F (20°C); 1280-1550 ohms at 212°F (100°C). If resistance is not as specified, replace compressor.