LEMON Manuals: Even more car manuals for everyone

"4" Position Switch Circuit Monitor

OPERATION REFERENCE

DTC P1723
Monitor execution Continuous
Monitor duration 10 seconds
ENABLE CONDITIONS

Parameter Minimum Maximum
Battery voltage 9 V -
Engine speed 400 -
CAN communication (U0073), (U0100) Normal condition or not monitored
TYPICAL MALFUNCTION THRESHOLDS

P1723 
Monitor voltage ≥ 4.19 V or < 0.91 V