LEMON Manuals: Even more car manuals for everyone

Generator Specifications

GENERATOR SPECIFICATIONS

Application Specification
Brush Length
Standard .41" (10.5 mm)
Limit (Minimum) .18" (4.5 mm)
Rotor Resistance 2.9 ohms
Rotor Slip Ring
Standard .567" (14.4 mm)
Limit (Minimum) .551" (14.0 mm)
Rotation Clockwise viewed from pulley side
Setting Voltage 13.6 - 14.4 V
Output (Maximum) 80A