Execution Condition

Secondary parameters Execution condition
Battery voltage
Estimated secondary oxygen sensor element temperature Integrated duty ratio of the secondary oxygen sensor heater operation from engine start
Secondary oxygen sensor offset signal
10.9 V or more
500°C (932°F) or more
11800% or more
1.8V or more and
2.2V or less